Service manual

AR-235/275 SIMULATION - 17
Operation/procedure
Counter data is displayed.
Operation/procedure (Pattern 7)
Each counter is cleared individually. (The history of each counter is
deleted when clearing)
Operation/procedure (Pattern 7)
Clear the counters individually.
Operation/procedure (Pattern 7)
Clear the counters individually.
Operation/procedure (Pattern 6)
Press the [OK] key.
Operation/procedure (Pattern 6)
Press the [OK] key.
Display items Jam contents
PI_TOP
SPF paper-in lead edge jam
PI_END
SPF paper-in rear edge jam
PO_TOP
SPF paper-out lead edge jam
PO_END
SPF paper-out rear edge jam
JAM_REV
SPF duplex reversion jam
ORG_SHORT
SPF short scale error
ORG_LONG
SPF long scale error
22-19
Purpose
Adjustment/setting/operation data output/check
(display/print)
Function
(Purpose)
Used to display the scanner mode counter.
Item
Trouble
SCANMODE
Scanner mode counter
24
24-1
Purpose
Data clear
Function
(Purpose)
Used to clear the misfeed counter, the misfeed history,
the trouble counter, and the trouble history. (The
counters are cleared after completion of maintenance.)
Item
Counter
(Initial screen) (Check screen)
1:JAM
JAM counter/JAM history
2:SPF JAM
SPF JAM counter/SPF JAM history
3:TROUBLE
Trouble counter/Trouble history
24-2
Purpose
Data clear
Function
(Purpose)
Used to clear the number of use (the number of prints)
of each paper feed section.
Section
Paper feed
Item
Counter
Sim22-12 SPF JAM1/5
XXXXXXX XXXXXXX
XXXXXXX XXXXXXX
XXXXXXX XXXXXXX
XXXXXXX XXXXXXX
Sim22-19 SCAN MODE
SCANMODE:nnnnnnnnn
Sim24-1 COUNTER CLR
1:JAM
2:SPF JAM
3:TROUBLE
2
Sim24-1 COUNTER CLR
1:JAM
2:SPF JAM
3:TROUBLE
ARE YOU SURE? 2
(Initial screen) (Check screen)
1:BYPASS
Manual feed counter
4:TRAY3
Tray 3 counter
2:TRAY1
Tray 1 counter
5:TRAY4
Tray 4 counter
3:TRAY2
Tray 2 counter
24-3
Purpose
Data clear
Function
(Purpose)
Used to clear the number data of use of the staple, the
SPF and scanning.
Item
Counter
(Initial screen) (Check screen)
1:SPF
SPF counter
2:SCAN
Scan counter
3:STAPLE
Stapler counter
24-4
Purpose
Data clear
Function
(Purpose)
Used to reset the maintenance counter.
Item
Counter
(Initial screen) (Check screen)
24-5
Purpose
Data clear
Function
(Purpose)
Used to reset the developer counter. (The developer
counter of the DV unit which is installed is reset.)
Section
Image process (Photoconductor/Developing/Transfer/
Cleaning)
Developer/Toner hopper
Item
Counter Developer
(Initial screen) (Check screen)
24-6
Purpose
Data clear
Function
(Purpose)
Used to reset the copy counter.
Item
Counter Copier
Sim24-2 COUNTER CLR
1:BYPASS 4:TRAY3
2:TRAY1 5:TRAY4
3:TRAY2
2
Sim24-2 COUNTER CLR
1:BYPASS 4:TRAY3
2:TRAY1 5:TRAY4
3:TRAY2
ARE YOU SURE? 2
Sim24-3 COUNTER CLR
1:SPF
2:SCAN
3:STAPLE
2
Sim24-3 COUNTER CLR
1:SPF
2:SCAN
3:STAPLE
ARE YOU SURE? 2
Sim24-4 COUNTER CLR
MAINTENANCE COUNTER
CLEAR
PRESS OK KEY
Sim24-4 COUNTER CLR
MAINTENANCE COUNTER
CLEAR
ARE YOU SURE?
Sim24-5 COUNTER CLR
DEVELOPER COUNTER
CLEAR
PRESS OK KEY
Sim24-5 COUNTER CLR
DEVELOPER COUNTER
CLEAR
ARE YOU SURE?