Specifications
AR-FX12 SIMULATIONS, FAX SOFTWARE SWITCH 6-49
76 5,6 Upper limit of call signal
OFF time
Used to set the upper limit of wait time from pulse (number of times) detection
of a call signal (CI) to the next CI signal pulse. When the next CI signal pulse is
not detected within the set range, the number of calls until then is cleared.
0 5sec
0
7,8 Not used 0
0
77 1-4 Call signal OFF no
detection time
Used to set the time to ignore OFF signal and regard as ON time continuing
after detection of call signal (CI) ON. This is to process PBX call signal (Ring,
Ring) as one call signal.
The set range is 0 - 150ms in the increment of 100ms by binary input.
0 600ms
1
1
0
5-8 Distinctive ring Used to set whether FAX call-in is made by distinctive ring or not.
When CI signal of other pattern than the set pattern is detected, auto call-in is
not made.
0 OFF Initial setup
0
0
0
78 1-8 Not used 0
0
0
0
0
0
0
0
79 1-8 Not used 0
0
0
0
0
0
0
0
80 1-8 Not used 0
0
0
0
0
0
0
0
SW
No.
Bit
No.
Item Switch selection and function USA Initial value Key
operator
Bit No. 5 6
5sec 0 0
10sec 0 1
15sec 1 0
20sec 1 1
Bit No. 5 6 7 8
OFF 0 0 0 0
STANDARD 0 0 0 1
Pattern 1 1 0 0 0
Pattern 2 0 1 0 0
Pattern 3 1 1 0 0
Pattern 4 0 0 1 0
Pattern 5 1 0 1 0
ON (Australia) 0 1 1 0
ON (Newzealand) 1 1 1 0
[06]SIMULATIONS ・ FAXSOFTWARESWITCH.fm 49 ページ 2004年10月26日 火曜日 午後3時44分