Specifications
AR-FX11 SIMULATIONS, FAX SOFTWARE SWITCH 6-29
U.S.A.: U.S.A. CA: Canada U.K: U.Kingdom GR: German FR: France
22 3,4 CNG send start
time
000000.5sec
00000
5,6 Tone/pulse default
setting
11111TONE YES
00000
7DPMUTE control 00000OFF
8 DP dial pulse
number process
00000Normal (N)
23 1 Not used 00000
2 Polarity inversion
monitor during
communication
Fixed to “NO” for North America. 00000NO
3 Polarity inversion
monitor during call-
out
Fixed to “NO” for North America. 00000NO
4-8 Before-dial time
(10PPS) setting
Binary input
0 (50ms) - 31 (360ms)
X (ms) = ( N x 10 ) + 50
00111Follow the
destination.
00111
00000
00000
11111
24 1-3 Before-dial time
(20PPS) setting
Binary input
0 (50ms) - 7 (120ms)
X (ms) = ( N x 10 ) + 50
0000050ms
00000
00000
4 Not used 00000
5-8 OFF HOOK wait
time
Binary input
Setting range
0 (50ms) - 15 (200ms)
X (ms) = (N x 10) + 50
00000100ms
11111
00000
11111
25 1-4 Make time (10PPS)
setting
Binary input
Setting range 26 - 41ms
1ms interval
11111Follow the
destination.
11010
11010
00010
5-8 Make time (20PPS)
setting
Binary input
Setting range 9 - 24ms
1ms interval
00000Fixed to 0
00000
00000
00000
26 1-5 DTMF signal send
time
Binary input
6 (60ms) - 31 (310ms)
X (ms) = ( N x 10 )
00000110ms
11111
00000
11111
11111
6-8 Minimum pause
time (DTMF)
setting
Binary input
0 (90ms) - 7 (160ms)
X (ms) = ( N x 10 ) + 90
00000120ms
11111
11111
27 1 Not used 00000
2-4 Before-dial time
(DTMF) setting
Binary input
0 (30ms) - 7 (100ms)
X (ms) = ( N x 10 ) + 30
0000050ms
11111
00000
SW
No.
Bit
No.
Item Switch serection and function
U.S.A.
CA U.K GR FR Initial value
Key operator
Bit No. 3 4
0.5sec 0 0
1.0sec 0 1
1.5sec 1 0
Bit No. 5 6
10PPS 0 0
20PPS 0 1
TONE 1 0
1ON 0OFF
1 10 - N 0 Normal (N)
1YES 0NO
1YES 0NO
[06]SIMULATIONS ・ FAXSOFTWARESWITCH.fm 29 ページ 2004年11月12日 金曜日 午後2時24分