Specifications
AR-FX11 SIMULATIONS, FAX SOFTWARE SWITCH 6-10
66 2 FAX soft SW initializing
Used to clear the FAX-related soft SW values except for the line signal adjustment value and the machine
adjustment value and set them to the default values (which differ depending on the country code).
3 FAX PWB memory check
Used to check read/write from/into the memory on the FAX PWB. The check result is displayed for each
memory.
Main
code
Sub
code
Contents Remark
Sim66-2 SOFT SW
Sim66-2
SOFT SW COUNTRY CODE
OK
Sim66-2
SOFT SW COUNTRY CODE
Sim66-2
SOFT SW COUNTRY CODE
COUNTRY CODE
Japan 00000000
1/26 SELECT UP DN
INITIAL
ARE YOU SURE? EXEC
Input of a value cannot be made.
OK
INITIAL
EXEC
INITIALIZED
Sim66-2 SOFT SW
COUNTRY CODE
Sweden 10100101
26/26 SELECT UP DN
Simulation code input window
1sec later
CA key : Simulation cancel
Interrupt key : Sub code input window
OK key : Settlement
START key : Settlement
C key : Disable
Return key : Disable
Selection
Japan 00000000
U.S.A. 10110101
U.K. 10110100
China 00100110
India 01010011
Taiwan 11111110
Australia 00001001
New Zealand 0111111 0
Singapore 10011100
Malaysia 01101100
Hong Kong 01010000
Middle east 11111101
Germany 00000100
France 00111101
Spain 10100000
Portugal 10001011
Denmark 00110001
Norway 10000010
Switzerland 10100110
Italy 01011001
Belgium 00001111
Luxembourg 01101001
Netherlands 01111011
Finland 00111100
Sweden 10100101
Completion of execution
(Highlighted during execution)
Sim66-3 MEMOR CHK
Sim66-3 MEMOR CHK
OK
Sim66-3 MEMOR CHK
Sim66-3 MEMOR CHK
1:DRAM 4:OPTION
2:SRAM 5:PAGE
3:FLASH 6:MODEM
( 1 - 6 ) X
DRAM
EXEC
OK
DRAM
CHECKING MEMORY
EXEC
DRAM
MEMORY CHECK
RESULT
OK
Sim66-3 MEMOR CHK
DRAM
MEMORY CHECK
RESULT
NG XXXXXXXX SUM
Execution normal end
(Highlighted during execution)
SIM66-3 initial window SIM66-3 initial window
NG XXXXXXXX SUM
NG XXXXXXXX A-BUS
NG XXXXXXXX DATA
NG XXXXXXXX D-BUS
NG XXXXXXXX ERASE
NG XXXXXXXX IO
CA key : Simulation cancel
Interrupt key : Sub code input window
10-key : Item selection
OK key : Settlement and execution of the input value
START key : Settlement of the input value
Return key : Returns to the selection window.
C key : Disable
*Interruption with C key during execution cannot be made.
Execution error end (Highlighted during execution)
Return Return
[06]SIMULATIONS ・ FAXSOFTWARESWITCH.fm 10 ページ 2004年11月12日 金曜日 午後2時24分