Specifications
AR-F14/PN1 TROUBLE SHOOTING 9-5
(13) F1-30, Communication error
(14) F1-37, Finisher Unit Back-Up Memory Fault
(15) F1-80, Finisher Unit Power Supply Fault
(16) F1-81, Feed Motor Fault
B. Puncher unit, option
(1) F1-32, Communication Faulty
(2) F1-33, Horizontal Registration Motor Fault (detail code: 01/02)
Cause/Trouble section Procedure Check Result Remedy
Finisher controller PCB,
Host machine DC controller PCB
1 Turn off and then on the host machine. Is the problem corrected? YES End.
Wiring 2 Is the wiring between the finisher controller PCB and the DC
controller PCB of the host machine normal?
NO Correct the wring.
Finisher controller PCB,
Host machine DC controller PCB
3 Try replacing the finisher controller PCB and the host machine
DC controller PCB. Is the problem corrected?
YES End.
Cause/Trouble section Procedure Check Result Remedy
Finisher controller PCB 1 Turn off and then on the host machine. Is the problem corrected? YES End.
NO Replace the finisher
controller PCB.
Cause/Trouble section Procedure Check Result Remedy
Finisher controller PCB,
Host machine DC controller PCB
1 Turn off and then on the host machine. Is the problem corrected? YES End.
Wiring 2 Is the wiring between the finisher controller PCB and the host
machine DC controller PCB normal?
NO Correct the wiring.
Power supply 3 Measure the voltage between CN1-1 (+) and CN1-3 (-)/CN2-1 (+)
and CN2-3 (-) on the finisher controller PCB. Is it 24 VDC?
YES Replace the finisher
controller PCB.
NO Replace the host
machine DC controller
PCB.
Cause/Trouble section Procedure Check Result Remedy
Stack feed roller (upper)
home position sensor (FRHPS)
1 Check the stack feed roller (upper) home position sensor.
Is it normal?
NO Replace the sensor.
Wiring 2 Is the wiring between the finisher controller PCB and the feed
motor normal?
NO Correct the wiring.
Feed roller 3 Try turning the stack feed roller (upper) shaft by hand.
Does the stack feed roller (upper) move up/down normally?
NO Correct the
mechanical system.
Feed motor (FFM),
Finisher controller PCB
4 Try replacing the feed motor. Is the problem corrected? YES End.
NO Replace the finisher
controller PCB.
Cause/Trouble section Procedure Check Result Remedy
Finisher controller PCB,
Punch controller PCB
1 Turn off and the on the host machine. Is the problem corrected? YES End.
Wiring 2 Is the wiring between the finisher controller PCB and the punch
controller PCB normal?
NO Correct the wiring.
Power supply 3 Measure the voltage between CN14-5 (+) and CN14-3 (-) on the
finisher controller PCB. Is it 24 VDC?
NO Replace the finisher
controller PCB.
YES Replace the punch
controller PCB.
Cause/Trouble section Procedure Check Result Remedy
Horizontal registration home position
sensor (PSHPS)
1 Check the horizontal registration home position sensor.
Is the sensor normal?
NO Replace the sensor.
Wiring 2 Is the wiring between the finisher controller PCB and the
horizontal registration home position sensor normal?
NO Correct the wiring.
Horizontal registration mechanism,
horizontal registration motor (FPSM)
3 Is there a fault in the horizontal registration mechanism? YES Correct the horizontal
registration
mechanism.
NO Replace the horizontal
registration motor.
Punch controller PCB,
Finisher controller PCB
4 Try replacing the punch controller PCB. Is the problem corrected? YES End.
NO Replace the finisher
controller PCB.
[09]TROUBLESHOOTING.fm 5 ページ 2004年4月19日 月曜日 午後1時42分