Unit installation
AR-C330 SELF DIAG MESSAGE AND TROUBLESHOOTING 10 - 3
F1 70 PCU PWB - sorter control PWB
communication trouble (PCU detection)
Sorter / PCU
MAIN PWB
Warm-up /
Initialize
Power
source-ON
80 Sorter power abnormality (Sorter side
detection)
Sorter All modes Power
source-ON
81 Sorter transport motor trouble (Sorter
side detection)
Sorter Sort/group
operation
mode
Power
source-ON
83 Sorter push bar motor trouble (Sorter
side detection)
Sorter Initializing Power
source-ON
87 Sorter staple unit oscillation motor
trouble (Sorter side detection)
Sorter Initializing Power
source-ON
89 Sorter bin shift motor trouble (Sorter
side detection)
Sorter Sort / Group
operation
mode
Power
source-ON
91 Bin paper sensor auto adjustment
trouble (Sorter side detection)
Sorter Sort/group
operation
mode
Power
source-ON
94 Sorter staple key trouble Sorter Staple Power
source-ON
F2 40 Toner concentration sensor trouble
(BLACK)
Developing All modes Power
source-ON
41 Toner concentration sensor trouble
(CYAN)
Developing All modes Power
source-ON
42 Toner concentration sensor trouble
(MAGENTA)
Developing All modes Power
source-ON
43 Toner concentration sensor trouble
(YELLOW)
Developing All modes Power
source-ON
44 Image density sensor trouble (BLACK)
(Transfer belt surface reflection
abnormality)
Image process
(Transfer)
Image density
correction
Power
source-ON
Print is disabled in USA. For the
other destinations, print is enabled.
However, the print density must be
forcibly decreased.
45 Image density sensor trouble (COLOR)
(Calibration plate reflection abnormality)
Image process
(Transfer)
Image density
correction
Power
source-ON
Print is disabled in USA. For the
other destinations, print is enabled.
However, the print density must be
forcibly decreased.
50 Drum marking detection trouble
(BLACK)
Image process
(OPC drum)
OPC drum
rotation
Power
source-ON
The error code is stored in the
trouble memory (print enabled).
51 Drum marking detection trouble (CYAN) Image process
(OPC drum)
OPC drum
rotation
Power
source-ON
The error code is stored in the
trouble memory (print enabled).
52 Drum marking detection trouble
(MAGENTA)
Image process
(OPC drum)
OPC drum
rotation
Power
source-ON
The error code is stored in the
trouble memory (print enabled).
53 Drum marking detection trouble
(YELLOW)
Image process
(OPC drum)
OPC drum
rotation
Power
source-ON
The error code is stored in the
trouble memory (print enabled).
54 Drum marking sensor gain adjustment
error (BLACK)
Image process
(OPC drum)
Image density
correction
Power
source-ON
Print is disabled in USA. For the
other destinations, print is enabled.
However, the print density must be
forcibly decreased.
55 Drum marking sensor gain adjustment
error (CYAN)
Image process
(OPC drum)
Image density
correction
Power
source-ON
Print is disabled in USA. For the
other destinations, print is enabled.
However, the print density must be
forcibly decreased.
56 Drum marking sensor gain adjustment
error (MAGENTA)
Image process
(OPC drum)
Image density
correction
Power
source-ON
Print is disabled in USA. For the
other destinations, print is enabled.
However, the print density must be
forcibly decreased.
57 Drum marking sensor gain adjustment
error (YELLOW)
Image process
(OPC drum)
Image density
correction
Power
source-ON
Print is disabled in USA. For the
other destinations, print is enabled.
However, the print density must be
forcibly decreased.
58 Process humidity sensor trouble Image process
(Transfer)
All modes Power
source-ON
The error code is stored in the
trouble memory (print enabled).
63 Temperature sensor trouble (Image
process)
Image process All modes Power
source-ON
The error code is stored in the
trouble memory (print enabled).
78 Trouble of image density sensor for
registration (Transfer belt surface
reflection ratio abnormality)
Image process All modes Power
source-ON
Main
code
Sub
code
Title (Content) Section
Operation
mode
Remedy NOTE