Unit installation

AR-C330 SELF DIAG MESSAGE AND TROUBLESHOOTING 10 - 21
F1 20 Case 2 Trouble
position/
cause
Alignment motor trouble /
Alignment plate home
position sensor trouble
(Rear side)
Remedy (Check) Check the
operations of the alignment
motor/alignment plate home
position sensor (Rear side).
(SIM 3-1/2)
(Repair) Replace the
alignment motor. / Replace
the alignment plate home
position sensor (Rear side).
(After work)
Case 3 Trouble
position/
cause
Finisher control PWB
trouble
Remedy (Check) Check the finisher
control PWB operation.
(SIM 3-1/2)
(Repair) Replace the
finisher control PWB. /
Power OFF-ON
(After work) Make various
adjustments related to the
finisher electric section.
(Install the EEPROM of the
defective finisher control
PWB to a new finisher
control PWB.)
Main
code
Sub
code
Title
PCU PWB - sorter control PWB
communication trouble (PCU
detection)
F1 70 Phenomena Display Lamp
Message
Detail Communication test error
after turning ON the power
or canceling a simulation.
Section Sorter / PCU MAIN PWB
Operation
mode
Warm-up / Initialize
Note
Case 1 Trouble
position/
cause
PCU MAIN PWB - Sorter
signal line connection
trouble
Remedy (Check) Check connection
of the signal line between
the PCU MAIN PWB and
the sorter.
(Repair) Repair or replace
the cable and the connector
between the PCUMAIN
PWB and the ICU MAIN
PWB. / Power Source-ON
(After-work)
Case 2 Trouble
position/
cause
Sorter control PWB trouble
Remedy (Check)
(Repair) Replace the sorter
control PWB. / Power
Source-ON
(After-work)
Main
code
Sub
code
Title
Finisher alignment trouble (Rear
side) (Finisher side detection)
F1 70 Case 3 Trouble
position/
cause
PCU MAIN PWB trouble
Remedy (Check)
(Repair) Replace the PCU
MAIN PWB. / Power
Source-ON
(After-work) Re-enter setup
values and adjustment
values. (Install the
EEPROM of the defective
PCU MAIN PWB to a new
PCU MAIN PWB.)
Main
code
Sub
code
Title
Sorter power abnormality (Sorter
side detection)
F1 80 Phenomena Display Lamp
Message
Detail Sorter control PWB +24V
power abnormality (Low
voltage)
Section Sorter
Operation
mode
All modes
Note
Case 1 Trouble
position/
cause
Bad connection between
the DC main PWB and the
sorter control PWB.
Remedy (Check) Check connection
between the DC main PWB
and the sorter control PWB.
(Repair) Repair or replace
the harness and the
connector between the DC
main PWB and the sorter
control PWB. / Power
Source-ON
(After-work)
Case 2 Trouble
position/
cause
Sorter control PWB trouble
Remedy (Check) Check the power
source in the sorter control
PWB. (SIM 3-2)
(Repair) Replace the sorter
control PWB. / Power
Source-ON
(After-work)
Main
code
Sub
code
Title
PCU PWB - sorter control PWB
communication trouble (PCU
detection)