Unit installation
AR-C330 SELF DIAG MESSAGE AND TROUBLESHOOTING 10 - 20
F1 15 Case 2 Trouble
position/
cause
Tray lift motor trouble / Tray
upper limit sensor trouble /
Tray lift motor rotation
sensor trouble / Tray height
sensor trouble
Remedy (Check) Check the
operations of the tray lift
motor / tray upper limit
sensor / tray lift motor
rotation sensor / tray height
sensor. (SIM 3-1/2)
(Repair) Replace the tray lift
motor. / Replace the tray
upper limit sensor. /
Replace the tray lift motor
rotation sensor. / Replace
the tray height sensor.
(After work)
Case 3 Trouble
position/
cause
Finisher control PWB
trouble
Remedy (Check) Check the
operation of the finisher
control PWB. (SIM 3-1/2)
(Repair) Replace the
finisher control PWB. /
Power OFF-ON
(After work) Make various
adjustments related to the
finisher electric section.
(Install the EEPROM of the
defective finisher control
PWB to a new finisher
control PWB.)
Main
code
Sub
code
Title
Finisher alignment trouble (Front
side) (Finisher side detection)
F1 19 Phenomena Display Lamp
Message
Detail In the initial operation, the
alignment plate home
position sensor signal OFF
is not recognized within the
specified time after starting
rotation of the alignment
motor. / In the initial
operation, the alignment
plate home position sensor
signal ON is not recognized
within the specified time
after starting rotation of the
alignment motor.
Section Finisher alignment
Operation
mode
Power ON
Note
Case 1 Trouble
position/
cause
Alignment mechanism
section trouble (Front side)
Remedy (Check) Check the
alignment mechanism
section. (Front side) (SIM 3-
1/2)
(Repair) Repair the
alignment mechanism
section (Front side). / Power
OFF-ON
(After work)
Main
code
Sub
code
Title
Finisher tray lift trouble (Finisher
side detection)
F1 19 Case 2 Trouble
position/
cause
Alignment motor trouble /
Alignment plate home
position sensor trouble
(Front side)
Remedy (Check) Check the
operations of the alignment
motor/alignment plate home
position sensor (Front side).
(SIM 3-1/2)
(Repair) Replace the
alignment motor. / Replace
the alignment plate home
position sensor. (Front side)
(After work)
Case 3 Trouble
position/
cause
Finisher control PWB
trouble
Remedy (Check) Check the finisher
control PWB operation.
(SIM 3-1/2)
(Repair) Replace the
finisher control PWB. /
Power OFF-ON
(After work) Make various
adjustments related to the
finisher electric section.
(Install the EEPROM of the
defective finisher control
PWB to a new finisher
control PWB.)
Main
code
Sub
code
Title
Finisher alignment trouble (Rear
side) (Finisher side detection)
F1 20 Phenomena Display Lamp
Message
Detail In the initial operation, the
alignment plate home
position sensor signal OFF
is not recognized within the
specified time after starting
rotation of the alignment
motor. / In the initial
operation, the alignment
plate home position sensor
signal ON is not recognized
within the specified time
after starting rotation of the
alignment motor. (Rear
side)
Section Finisher alignment
Operation
mode
Power ON
Note
Case 1 Trouble
position/
cause
Alignment mechanism
section trouble (Rear side)
Remedy (Check) Check the
alignment mechanism
section (Rear side). (SIM 3-
1/2)
(Repair) Repair the
alignment mechanism
section (Rear side). / Power
OFF-ON
(After work)
Main
code
Sub
code
Title
Finisher alignment trouble (Front
side) (Finisher side detection)