Service manual

AR-C200P Rev.5 143 /
A Paper thickness error (Err Code 323, 324)
Is the sensor connector connected?
NO Connect the connecter.
YES Is the sensor cable disconnected?
NO Replace the cable.
YES Is +5V output to the PU board REG 13pin?
NO Replace the PU board.
YES IS GND connection made to the PU board REG 15pin?
NO Replace the PU board.
YES Is pulse signal 5ms ON 10% Duty output to the PU board REG 16pin?
(Disabled on field due to sync usage.)
NO Replace the PU board.
YES Turn ON the power and check the media thickness. Is the error released?
NO Replace the sensor.
YES: End.