Service manual

AR-5127 SIMULATION 8 - 21
Note: Executable only when the finisher is not installed.
Operation/procedure
Select the language to be used according to the table below.
This setup varies in connection with SIM 26-6 (Destination setup).
Operation/procedure
Input the set value with the 10-key and press the [OK] key.
This setup varies in connection with SIM 26-6 (Destination setup).
Operation/procedure
Used to set whether the trouble history of SIM 22-4 is displayed as
one-time trouble or as a number of times of troubles continuously
occurred when two or more troubles of the same kind occurred.
Enter the set value with 10-key, and press [OK] key.
Operation/procedure
Input the set value with the 10-key and press the [OK] key.
Note: Executable only with SRU (AR models).
Operation/procedure
Input the set value with the 10-key and press the [OK] key.
Note: Executable only with CRU (DM models).
Display
items
Content
Setting
range
Default
0:OFF
Paper is discharged to No. 1
paper exit port.
0-1 0
1:ON
Used to discharge paper to the
job separator tray (No. 2 paper
exit port).
26-22
Purpose Setting
Function
(Purpose)
Used to set the specification (language display) for the
destination.
Item Specifications
Display items
Setting
range
Default
0:JAPANESE 11:GREEK
0-20 Depends on
the
destination.
1:ENG.US 12:POLISH
2:ENG.UK 13:HUNGARIAN
3:FRENCH 14:CZECH
4:GERMAN 15:RUSSIAN
5:ITALIAN 16:FINNISH
6:DUTCH 17:NORWEGIAN
7:SWEDISH 18:DANISH
8:SPANISH 19:CHINESE
9:PORTUGUESE 20:TAIWANESE
10:TURKISH
26-30
Purpose Setting
Function
(Purpose)
Used to set the operation mode for CE mark.
Item Specifications Operation mode (Common)
Display items Setting range
Default
Japan, SEC, SECL,
SCA, SEF, Taiwan
Others
0:OFF
0-1 0 1
1:ON
Sim26-22 LANGUAGE
LANGUAGE 0
(0:JAPANESE
1:ENG.US 2:ENG.UK
1/3 [ 0- 19] 0
Sim26-30 CE MARK
CE MARK CONTROL 0
(0:OFF 1:ON)
[ 0- 1] 0
26-35
Purpose Setup
Function
(Purpose)
Used to set the mode of trouble memory.
Item Specifications
Display item Content Set range Default
0:ONCE
When two or more troubles
occur, only one is registered.
0-1 0
1:ANY
All the troubles occurred are
registered.
26-36
Purpose Setting
Function
(Purpose)
Used to set whether to stop when the maintenance life
is reached.
Item Operation
Display items Content Setting range Default
0:STOP
Stop 0-1 1
1:NON STOP
Non stop
26-37
Purpose Setting
Function
(Purpose)
Used to set whether to stop when the developer life is
reached.
Item Operation
Display items Content Setting range Default
0:STOP
Stop 0-1 0
1:NON STOP
Non stop
Sim26-35 TROUBLE
TROUBLE MODE 0
(0:ONCE 1:ANY)
[ 0- 1] 0
Sim26-36 MAINTESTOP
MAINTENANCE OVER 0
(0:STOP
1:NON STOP)
[ 0- 1] 0
Sim26-37 DEVE. STOP
DEVE. LIFE OVER 0
(0:STOP
1:NON STOP)
[ 0- 1] 0