Specifications

AR-168N/168L TEST COMMAND, TROUBLE CODES 10 - 8
10 00 Toner motor operation
(TONER MOTOR)
[Function]
When [ENTER/START] key is pressed, the toner motor is rotated for 30sec.
After completion of this process, the machine goes into the main code entry standby mode.
[Operation]
14 00 Cancel of trouble other than
U2 (TRBL CANC.)
[Function]
Used to cancel troubles other than U2.
Cancel troubles such as H trouble which writes data into EEPROM, and perform hardware reset.
[Operation]
16 00 U2 trouble cancel (U2 TRBL
CANC.)
[Function]
Used to cancel U2 trouble.
When [ENTER/START] key is pressed, check sum of the total counter in the EEPROM is rewritten
and hardware reset is made.
[Operation]
20 01 Maintenance counter clear
(M-CNT CLR.)
[Function]
When [ENTER/START] key is pressed, the maintenance count value is cleared and "000,000" is dis-
played.
[Operation]
21 01 Maintenance cycle setting
(M-CYCLE)
[Function]
The code of the currently set maintenance cycle value is displayed (initial display) and the set data
are saved.
[Operation]
22 01 Maintenance counter display
(M-CNT)
[Function]
The maintenance counter is displayed.
[Operation]
Main
code
Sub
code
Contents Details of function/operation
1) Initial display
10-00 TONER MOTOR
EXECUTING...
1) Initial display
14-00 TRBL CANC.
CLEARED
1) Initial display
16-00 U2 TRBL CANC.
CLEARED
1) Initial display
20-01 M-CNT CLR.
CLEARED 000,000
Code Setting Remark
0 3,000 sheets
1 6,000 sheets
2 9,000 sheets
3 13,000 sheets
4 25,000 sheets Default
5 Free (999,999 sheets)
1) The current set value is
displayed.
2)
[→
/10KEY]
2) [
/10KEY]
3) [ENTER/START]
21-01 M-CYCLE
4:25,000 ( 0-5 )
21-01 M-CYCLE
5:FREE ( 0-5 )
21-01 M-CYCLE
3:13,000 ( 0-5 )
21-01 M-CYCLE
5:FREE ( 0-5 )
1) Initial display
22-01 M-CNT
***,***
10_TESTCOMMAND.fm 8 ページ 2005年11月18日 金曜日 午後5時37分