Service manual
24
LC-13E1U/UB/UW
LC-15E1U/UB/UW
19 V255 255 255 Gradation power reference voltage
V255 BIAS 127 127 Gradation power reference voltage
V235 226 226 Gradation power reference voltage
V235 BIAS 127 127 Gradation power reference voltage
V176 138 137 Gradation power reference voltage
V176 BIAS 150 150 Gradation power reference voltage
V112 103 103 Gradation power reference voltage
V112 BIAS 170 170 Gradation power reference voltage
V64 72 73 Gradation power reference voltage
V64 BIAS 40 40 Gradation power reference voltage
V32 62 62 Gradation power reference voltage
V32 BIAS 45 45 Gradation power reference voltage
20 V21 49 50 Gradation power reference voltage
V21 BIAS 50 50 Gradation power reference voltage
V17 45 45 Gradation power reference voltage
V17 BIAS 55 55 Gradation power reference voltage
V7 29 29 Gradation power reference voltage
V7 BIAS 65 65 Gradation power reference voltage
V0 0 0 Gradation power reference voltage
V0 BIAS 80 130 Gradation power reference voltage
VGL ADJ 27 27 VGL bias setting
VGL COM 215 215 VGL COM setting
COM 181 181 COM amplitude setting
G/A READDATA 00 00 00 00 Controller read data setting
G/A READDATA WAIT WAIT Read execution
Gradation & COM settings
21 3D Y/C 0 0 3D ON/OFF setting
3D Y/C DATA 0 0 3D YC data write & read
3D Y/C DATA WAIT WAIT Write & read execution
LSYNC 625 625 Sync ID threshold level (TV)
HSYNC 655 655 Sync ID threshold level (TV)
AVSYNC 5000 5000 Sync ID threshold level (external input)
VPC FP20H
DATA0000 DATA0000
VPC data read value
VPC FP21H
DATA0000 DATA0000
VPC data read value
VPC FP13H
DATA0000 DATA0000
VPC data read value
MSP DEMO200H
DATA0000 DATA0000
MSP data read value
L ERROR WAIT 15s 15s Lamp error detect wait time
L ERROR H TIME 1.0s 1.0s Lamp error detect time
VPC I2C 20H 24 24 Sync control setting (Only for Ver. 1.8)
Three-dimensional settings & sync ID settings
22 DENKA PORT OFF OFF Power off mode setting
DENKA TESTP 00 00 Power off mode setting
DENKA TESTP2 30ms 30ms Power off mode setting
FP12TIM 700 700 Measure against vertical baund
REMOCON CODE 000 000 Received remote control code display
Power off mode settings & Measure against baund setting
Page Item
Initial setting
Function Adjust/modify
LC-13E1U LC-15E1U