Service manual
23
LC-13E1U/UB/UW
LC-15E1U/UB/UW
17 AFT UP 2.7 2.7 AFT reference voltage
AFT DOWN 1.8 1.8 AFT reference voltage
NTSC 01 8C 8C Initial settings
NTSC 02 C0 C0 Various settings
NTSC 03 81 81 RCUTOFF
NTSC 04 00 00 GCUTOFF
NTSC 05 81 81 BCUTOFF
NTSC 06 0B 0B Horizontal display position
NTSC 07 10 10 Vertical display position
NTSC 08 00 00 UV data phase delay
NTSC 09 4C 4C Panel clock adjustment
NTSC 0A 4B 4B Display screen top/bottom mask position
NTSC 10 80 80 Test pattern display
NTSC 11 00 00 Test pattern data
NTSC 12 00 00 Horizontal display mask (left) position
NTSC 13 00 00 Horizontal display mask (right) position
NTSC E0 00 00 FIFO TEST
NTSC E1 03 03 Sync polarity reversal
NTSC F0 07 07 OFL terminal operation setting
NTSC F1 00 00 Inverter frequency setting
NTSC F2 00 00 Inverter duty setting
NTSC F3 C0 C0 Dimmer frequency setting, lower level
NTSC F4 00 00 Dimmer frequency setting, upper level
NTSC F5 00 00 Dimmer PWM setting, lower level
NTSC F6 00 00 Dimmer PWM setting, upper level
NTSC F7 00 00 OFL 1/2 phase
NTSC 14 02 02 System clock setting
G/A TEST PATERN OFF OFF Gradation test pattern display LCD controller IC test pattern
18 PAL 01 8E 8E Initial settings
PAL 02 C8 C8 Various settings
PAL 03 81 81 RCUTOFF
PAL 04 00 00 GCUTOFF
PAL 05 81 81 BCUTOFF
PAL 06 13 13 Horizontal display position
PAL 07 18 18 Vertical display position
PAL 08 O2 O2 UV data phase delay
PAL 09 4C 4C Panel clock adjustment
PAL 0A 4A 4A Display screen top/bottom mask position
PAL 10 80 80 Test pattern display
PAL 11 00 00 Test pattern data
PAL 12 00 00 Horizontal display mask (left) position
PAL 13 00 00 Horizontal display mask (right) position
PAL E0 00 00 FIFO TEST
PAL E1 03 03 Sync polarity reversal
PAL F0 07 07 OFL terminal operation setting
PAL F1 00 00 Inverter frequency setting
PAL F2 00 00 Inverter duty setting
PAL F3 BD BD Dimmer frequency setting, lower level
PAL F4 00 00 Dimmer frequency setting, upper level
PAL F5 00 00 Dimmer PWM setting, lower level
PAL F6 00 00 Dimmer PWM setting, upper level
PAL F7 00 00 OFL 1/2 phase
PAL 14 02 02 System clock setting
CLOSED CAPTION 15 15 Closed caption thresh level
CCD ISO 16 16 Closed caption phase setting
AIR SERCH 1.6 1.6 Last synchronous judging frequency at the
AIR CH SEARCH
Search AFT reference settings & LCD controller settings
Page Item
Initial setting
Function Adjust/modify
LC-13E1U LC-15E1U