Service manual
AL-2051 SIMULATION, TROUBLE CODES 10 - 11
26 02 SPF/RSPF setup [Function]
When this simulation is executed, the current set SPF/RSPF is displayed. Enter the code num-
ber corresponding to the desired SPF/RSPF and press [ENTER]/[START] key to save the set-
ting.
[Operation]
04 Machine duplex setup [Function]
When this simulation is executed, the current set duplex is displayed. Enter the code number
corresponding to the desired duplex and press [ENTER]/[START] key to save the setting.
[Operation]
The operation is similar to simulation 26-02.
06 Destination setup [Function]
When this simulation is executed, the current set destination is displayed. Enter the code num-
ber corresponding to the desired destination and press [ENTER]/[START] key to save the set-
ting.
Note 1:
With a change of the setting, the counter for ‘AE limit setting’ is to be cleared to zero (SIM46-
30). The setting of the tray, if the paper size for it is set to the size of inch series, is to be
changed to the tray for the “Letter”. However, the setting of the tray, if the size of the paper for it
is set to any other size, is to be changed to the “A4”.
Note 2:
For any other models than those for Japan, the mark “-” is to be displayed, if the code 2 is
selected.
[Operation]
The operation is similar to simulation 26-02.
07 Machine conditions check [Function]
When this simulation is executed, the current machine setting is displayed.
[Operation]
Main
code
Sub
code
Contents Details of function/operation
Code number SPF/RSPF Display item
0 SPF NO SPF OFF
1 SPF YES SPF ON
2 RSPF YES RSPF ON
1) The current set value is
displayed.
2) [Numeric] key or [ ] key
2) [Numeric] key or [ ] key
3) [ENTER]/[START] key
26-02 SPF/RSPF
1:SPF ON (0- 2)
26-02 SPF/RSPF
0:SPF OFF (0- 2)
26-02 SPF/RSPF
2:RSPF ON (0- 2)
26-02 SPF/RSPF
2:RSPF ON (0- 2)
Code number Duplex Display item
0 Duplex NO OFF
1 Duplex YES ON
Code number Destination Display item
0 Inch series INCH
1 EX Japan AB series AB
2 Japan AB series JAPAN
3 China CHINA
CPM Copy quantity Remark
20 CPM 20
1) The machine setting is displayed.
26-07 CPM
20 CPM