Service manual
AL-2051 SIMULATION, TROUBLE CODES 10 - 2
4. Descriptions of various simulations
50 01 Lead edge image position
06 Copy lead edge position adjustment (RSPF)
10 Center offset adjustment
12 Document off-center adjustment
18 Memory reverse position adjustment in duplex
copy
19 Duplex copy rear edge void adjustment
51 02 Resist quantity adjustment
53 08 RSPF scan position automatic adjustment
61 03 Polygon motor check (HSYNC output check)
63 01 Shading check
02 Black level automatic correction
12 Light quantity stabilization wait time setting
13 Light quantity stabilization band setting
64 01 Self print
Sim
No.
Sub
code
Operation
Main
code
Sub
code
Contents Details of function/operation
1 01 Mirror scan operation [Function]
When [ENTER]/[START] key is pressed, the home position is checked and the mirror base per-
forms full scan at the speed of the set magnification ratio.
During operation, the set magnification ratio is displayed.
The mirror home position sensor status is displayed with the "Copy mode lamp".
(When the mirror is in the home position, the lamp lights up.)
During operation, the copy lamp lights up.
When [Clear] key is pressed, if the operation is on the way, it is terminated and the machine
goes to the sub code entry standby mode.
[Operation]
02 Mirror home position sensor
(MHPS) status display
[Function]
Monitors the mirror home position sensor, and makes the "Copy mode lamp". Turn on during
the sensor ON status.
[Operation]
06 Aging of mirror scanning [Function]
When [ENTER]/[START] key is pressed, the mirror base performs full scan at the speed of the
set magnification ratio.
During operation, the set magnification ratio is displayed.
After 3sec, the mirror base performs full scan again.
[Operation]
The operation is similar to simulation 1-01.
2 01 RSPF aging operation [Function]
When [ENTER]/[START] key is pressed, the set magnification ratio is obtained. For the SPF, the
single-face document transport is performed. For the RSPF, the duplex document transport is
performed.
However, the operating conditions don't matter and the operation is not stopped even in case of
a jam. Also the magnification ratio is displayed on the LCD/display.
[Operation]
The operation is similar to simulation 1-01.
1) Initial display 2) [ZOOM] key
2) [ ] key
2) [ ] key
3) [ENTER]/[START] key
01-01 SCAN CHK
- 100% +
01-01 SCAN CHK
- 78% +
01-01 SCAN CHK
- 99% +
01-01 SCAN CHK
- 101% +
01-01 SCAN CHK
EXECUTING... - 78% +
1) Initial display
01-02 MHP-SENSOR
EXECUTING...