Service manual
AL-2030/2040CS/2050CS SIMULATION, TROUBLE CODES 10 - 14
26 43 Side void setup [Function]
When this simulation is executed, the currently set code of the side void quantity is displayed
(initial display), and the set data are saved. (Setting range: 0 – 10, Default: 4 (= One side
2.0mm))
* When the adjustment value is increased by 1, the side void is changed as follows:
Side void adjustment: The side void is increased by 0.5mm. (The side void of "Set value x
0.5mm" is made.)
[Operation]
The operation is similar to simulation 09-04.
54 γ life correction setting [Function]
Used to set the γ life correction.
When this simulation is executed, the current set code number is displayed.
Enter the desired code number and press [ENTER]/[START] key to save the setting.
(Setting range: 0 – 1, default: 1)
[Operation]
The operation is similar to simulation 26-02.
62 Energy-save mode copy
lamp setup
[Function]
Used to set half-ON /OFF of the copy lamp in the pre-heat mode.
When this simulation is executed, the current set code number is displayed. Enter the desired
code number and press [ENTER]/[START] key to save the setting.
[Operation]
The operation is similar to simulation 26-02.
30 01 Paper sensor status display [Function]
The paper sensor status is displayed on the LCD/LED.
∗ Since the manual paper feed sensor is a single bypass sensor, its status is not displayed.
∗ The width sensor is available only in the FAX models.
[Operation] (AL-2050CS only)
Main
code
Sub
code
Contents Details of function/operation
Code Setting Remark
00 mm
10.5 mm
21.0 mm
31.5 mm
4 2.0 mm Default
52.5 mm
63.0 mm
73.5 mm
84.0 mm
94.5 mm
10 5.5 mm
Code number Setting Display item Remark
0OFFOFF
1 ON ON Default
Code number Setting Display item Remark
0Copy lamp OFF OFF
1 Copy lamp half-ON ON Default
Sensor
Display item
(AL-2050CS)
Display lamp (AL-2030/2040CS)
Paper exit sensor POD Photoconductor cartridge replacement lamp
Paper entry sensor PPD1 Developer cartridge replacement lamp
Duplex sensor PPD2 JAM lamp
No. 2 tray paper feed sensor PPD3 2nd cassette lamp
New drum cartridge sensor DRST Zoom lamp
1) Initial display 2) When sensor ON
30-01 P-SENSOR
30-01 POD PD1 PD2
PPD1 PPD2 PPD3 DRST