Specifications

AL-1551 SIMULATION, TROUBLE CODES 10-6
26 20 Rear edge void setup
(Operation/Procedure)
1. When this simulation is executed, the currently set code number of rear edge void setting is displayed.
2. Enter the code number of rear edge void setting and press the START key, and the setting will be changed.
30 CE mark conformity control ON/OFF setup
(Operation/Procedure)
1. When this simulation is executed, the currently set code number of CE mark application is displayed.
2. Enter the code number of CE mark application and press the START key, and the setting will be changed.
38 Cancel of stop at drum life over
(Operation/Procedure)
1. When this simulation is executed, the currently set code number is displayed.
2. Enter the code number and press the START key, and the setting will be changed.
39 Memory capacity setup
(Operation/Procedure)
1. When this simulation is executed, the currently set code number is displayed.
2. Enter the code number and press the START key, and the setting will be changed.
40 Polygon motor OFF time setup
(Operation/Procedure)
1. When this simulation is executed, the currently set code number is displayed.
2. Enter the code number and press the START key, and the setting will be changed.
Main
code
Sub
code
Content
Code number Rear edge void setting
0 Rear edge void allowed
1 Rear edge void not allowed
Code number CE mark application setting
0 CE mark application control OFF
1 CE mark application control ON
Code number Setting
0 Stop at drum life over
1 Stop cancel at drum life over
Code number Setting
0No memory
1 4 Mbyte
2 6 Mbyte
Code number Setting
0 0 sec
1 30 sec
2 60 sec
3 90 sec