Service manual

AL-1661CS TEST COMMAND, FAX SOFT SWITCH, TROUBLE CODES 10 - 16
43 05 Fusing temperature setting
in duplex copy (FU TEMP
DPLX)
[Function]
In the case of duplex copy, the shift temperature set with this test command is applied to the fusing
temperature.
When this test command is executed, the current set code number is displayed.
Enter the desired code number and press [ENTER/START] key to save the setting.
[Operation]
The operation is similar to test command 21-01.
09 Postcard size paper fusing
control setting (FU CTR P-
CARD) (Japan model only)
[Function]
When this test command is executed, the current set code number is displayed.
Enter the desired code number and press [ENTER/START] key to save the setting.
Setting" is default for Japan. However, there is no schedule for production of the Japan model.
[Operation]
The operation is similar to test command 21-01.
11 Postcard size paper fusing
temperature setting (FU
TEMP P-CARD) (Japan
model only)
[Function]
When this test command is executed, the current set code number is displayed.
When [
//10KEY] key is pressed, setting is changed. When [ENTER/START] key is pressed, set-
ting is written into the EEPROM. The machine goes into the sub code entry standby mode.
Applied only to the Japan model. However, there is no schedule to produce the Japan model. Set-
ting is reflected only when ON with test command 43-09.
[Operation]
The operation is similar to test command 21-01.
14 Fusing start temperature
setting (FU TEMP START)
[Function]
When this test command is started, the currently set code number is displayed.
Press [
//10KEY] to switch the setting, and press [ENTER/START] key to save it to the EEPROM.
The machine goes to the sub code entry standby mode.
[Operation]
The operation is similar to test command 21-01.
Main
code
Sub
code
Contents Details of function/operation
Code Shift temperature (°C) Remark
0 ±0 Default
1-8
2-6
3-4
4-2
0
6+2
7+4
8+6
9+8
Code Shift temperature (°C) Display item Remark
0 Cancel OFF Default
1 Setting ON
Code Shift temperature (°C) Remark
0 160
1 165
2 170
3 175
4 180
5 185
6 190
7 195 Default
8 200
Code Set temperature (°C) Remark
0 160
1 165
2 170
3 175
4 180
5 185
6 190
7 195 Default
8 200