Service manual

AL-1661CS TEST COMMAND, FAX SOFT SWITCH, TROUBLE CODES 10 - 8
10 00 Toner motor operation
(TONER MOTOR)
[Function]
When [ENTER/START] key is pressed, the toner motor is rotated for 30sec.
After completion of this process, the machine goes into the main code entry standby mode.
[Operation]
14 00 Cancel of trouble other than
U2 (TRBL CANC.)
[Function]
Used to cancel troubles other than U2.
Cancel troubles such as H trouble which writes data into EEPROM, and perform hardware reset.
[Operation]
16 00 U2 trouble cancel (U2 TRBL
CANC.)
[Function]
Used to cancel U2 trouble.
When [ENTER/START] key is pressed, check sum of the total counter in the EEPROM is rewritten
and hardware reset is made.
[Operation]
22 04 JAM total counter display
(JAM TTL CNT)
[Function]
The JAM total counter is displayed.
[Operation]
05 Total counter display (TTL
CNT)
[Function]
The total counter value is displayed.
[Operation]
08 SPF counter display (SPF
CNT)
[Function]
The SPF counter is displayed.
[Operation]
11 FAX-related counter display [Function]
The FAX-related counter is displayed.
[Operation]
Main
code
Sub
code
Contents Details of function/operation
1) Initial display
10-00 TONER MOTOR
EXECUTING...
1) Initial display
14-00 TRBL CANC.
CLEARED
1) Initial display
16-00 U2 TRBL CANC.
CLEARED
1) Initial display
22-04 JAM TTL CNT
***,***
1) Initial display
22-05 TTL CNT
***,***
1) Initial display
22-08 SPF CNT
***,***
1) Initial display
[CLEAR] key: FAX control is terminated.
2) Select 1
("xxx,xxx" is the current value.)
[CLEAR] key: Returns to "1) Initial display".
2) Select 2
("xxxx: xxx. xx" is the current value.)
[CLEAR] key: Returns to "1) Initial display".
SELECT COUNTER
1:PAGE 2:TIME
SEND PAGE:xxx,xxx
RECV PAGE:xxx,xxx
TX TIME:xxxx:xx.xx
RX TIME:xxxx:xx.xx