Service manual
AL-1661CS TEST COMMAND, FAX SOFT SWITCH, TROUBLE CODES 10 - 57
S
W
102
1 Scan effective image
area main scan left
edge image loss (OC)
Binary input
96 dots
0
2 Bit No.
Set range
1234
0 to 360 dots
24 dot interval
1
3 0
4 0
5 Scan effective image
area main scan right
edge image loss (OC)
Binary input
96 dots
0
6 Bit No.
Set range
5678
0 to 360 dots
24 dot interval
1
7 0
8 0
S
W
103
1 Scan effective image
area sub scan lead
edge image loss (OC)
Binary input
96 lines
0
2 Bit No.
Set range
1234
0 to 240 line
16 line interval
1
3 1
4 0
5 Scan effective image
area sub scan rear edge
image loss (OC)
Binary input
144 lines
1
6 Bit No.
Set range
5678
0 to 240 line
16 line interval
0
7 0
8 1
S
W
104
1 Scan effective image
area main scan left
edge image loss (SPF
back surface)
Binary input
96 dots
0
2 Bit No.
Set range
1234
0 to 360 dots
in the interval of 24 dots
1
3 0
4 0
5 Scan effective image
area main scan right
edge image loss (SPF
back surface)
Binary input
96 dots
0
6 Bit No.
Set range
5678
0 to 360 dots
in the interval of 24 dots
1
7 0
8 0
S
W
105
1 Scan magnification ratio
adjustment (OC main
scan)
1: – 0: + + 0
2 Binary input
0%
0
3 Bit No.
Set range
2345678
0 to ±12.7%
0.1% interval
0
4 0
5 0
6 0
7 0
8 0
S
W
106
1 Scan magnification ratio
adjustment (OC sub
scan)
1: – 0: + + 0
2 Binary input
0%
0
3 Bit No.
Set range
2345678
0 to ±12.7%
0.1% interval
0
4 0
5 0
6 0
7 0
8 0
S
W
107
1 Scan magnification ratio
adjustment (SPF back
surface main scan)
1: – 0: + + 0
2 Binary input
0%
0
3 Bit No.
Set range
2345678
0 to ±12.7%
0.1% interval
0
4 0
5 0
6 0
7 0
8 0
S
W
108
1 Scan magnification ratio
adjustment (SPF back
surface sub scan)
1: – 0: + + 0
2 Binary input
0%
0
3 Bit No.
Set range
2345678
0 to ±12.7%
0.1% interval
0
4 0
5 0
6 0
7 0
8 0
SW
NO.
Data
No.
Item Switch selection and contents of functions Initial value Remark