Service manual
AL-1661CS TEST COMMAND, FAX SOFT SWITCH, TROUBLE CODES 10 - 53
S
W
75
1 Inhibited to use 0
2 0
3 Communication end
sound (Buzzer sound
length) setting
Bit No. 3 4
3sec
0
Communication error
sound is generated
even in silent setup
Refer to User program
“BEEP LENGTH”.
When a value outside
the set range is set,
the initial value is set.
3sec 0 0
1sec 0 1
4 Silent 1 0
0
5 Print effective image
area main scan void
Binary input
48 dots
0
6 Bit No.
Set range
5678
0 to 240 dots
16 dots interval
0
7 1
8 1
S
W
76
1 Scan magnification ratio
adjustment (SPF main
scan)
1: – 0: + + 0
2 Binary input
0%
0
3 Bit No.
Set range
2345678
0 to ±12.7%
0.1% interval
0
4 0
5 0
6 0
7 0
8 0
S
W
77
1 Scan magnification ratio
adjustment (SPF sub
scan)
1: – 0: + + 0
2 Binary input
0%
0
3 Bit No.
Set range
2345678
0 to ±12.7%
0.1% interval
0
4 0
5 0
6 0
7 0
8 0
S
W
78
1 Print magnification
ration adjustment (main
scan)
1: – 0: + + 0
2 Binary input
0%
0
3 Bit No.
Set range
2345678
0 to ±12.7%
0.1% interval
0
4 0
5 0
6 0
7 0
8 0
S
W
79
1 Print magnification
ration adjustment (sub
scan)
1: – 0: + + 0
2 Binary input
0%
0
3 Bit No.
Set range
2345678
0 to ±12.7%
0.1% interval
0
4 0
5 0
6 0
7 0
8 0
S
W
80
1 Destination information Binary input
North America
1
2 Bit No. 12345678 0
3 North America: 1 0 1 1 0 1 0 1 1
4 1
5 0
6 1
7 0
8 1
S
W
81
1 Language information Binary input
American
English
0 Only command
receive from the main
unit can be rewritten.
2 Bit No. 12345678
1: American English
0
3 0
4 0
5 0
6 0
7 0
8 1
SW
NO.
Data
No.