Service manual

AL-1661CS TEST COMMAND, FAX SOFT SWITCH, TROUBLE CODES 10 - 42
S
W
15
1 Busy tone detection
time (Lower limit)
1: 350ms 0: 250ms
250ms 0
2 Busy tone detection
time (Upper limit)
1: 650ms 0: 750ms
750ms 0
3 Busy tone detection
time (Lower limit 2)
1: 150ms 0: Follows SW15-1.
Follows SW15-1. 0
4 Signal send level Binary input
12dBm
0 When a value outside
the set range is set,
the initial value is set.
5 Bit No.
Set range
45678
0 (0dBm) to 26 (26dBm)
1
6 1
7 0
8 0
S
W
16
1 Modem speed
(V.33 mode or less)
Bit No. 1234
V.17 14.4kbps
1V.27 2400bps 0 0 0 0
V.29 9600bps 0 0 0 1
2 V.27 4800bps 0 0 1 0
0V.29 7200bps 0 0 1 1
V.33 14.4kbps 0 1 0 0
3 V.33 12.0kbps 0 1 1 0
0V.17 9600bps 1 0 0 1
V.17 12.0kbps 1 0 1 0
4 V.17 7200bps 1 0 1 1
0
V.17 14.4kbps Others
5 Modem speed in
reception fixed
Bit No. 5 6
No fixing
0No fixing 0 0
V.29-9600BPS 0 1
6 V.27ter-4800BPS 1 0
0
V.17-14400BPS 1 1
7 Inhibited to use 0
8 0
S
W
17
1 Inhibited to use 0
2 MH fixed (Except for
SG3)
1: Yes 0: No (depending on the other
partys machine)
No 0
3 ECM MMR (Except for
SG3)
1: Yes 0: No
Yes 1
4 ECM JBIG (Except for
SG3)
1: Yes 0: No
Yes 1
5 Inhibited to use 0
6 MH fixed (in SG3) 1: Yes 0: No (depending on the other
partys machine)
No 0
7 ECM MMR (in SG3) 1: Yes 0: No Yes 1
8 ECM JBIG (in SG3) 1: Yes 0: No Yes 1
S
W
18
1 Inhibited to use 1
2 1
3 0
4 1
5 0
6 0
7 0
8 0
S
W
19
1 Inhibited to use 0
2 1
3 0
4 0
5 0
6 Recording table
automatic print
1: Yes 0: No
No 0
Refer to User program
AUTO LISTING.
7 Inhibited to use 0
8 0
SW
NO.
Data
No.
Item Switch selection and contents of functions Initial value Remark