Service manual
AL-1661CS TEST COMMAND, FAX SOFT SWITCH, TROUBLE CODES 10 - 39
6. Soft switch list
∗ When outside the set range, the default value is automatically set.
∗ Never change the soft switch setup which are inhibited to use.
SW
NO.
Data
No.
Item Switch selection and contents of functions Initial value Remark
S
W
1
1 Image quality priority
selection
Bit No. 1 2
Normal
0
Refer to User program
“RESO.PRIORITY”.
When a value outside
the set range is set,
the initial value is set.
Normal 0 0
2Fine01
0Super fine 1 0
3 Inhibited to use 0
4 Auto/Manual default
setup
1: Manual reception 0: Automatic reception
Automatic
reception
0
Manual reception can
be set only when
external telephone is
connected.
5 Send request protection 1: Not protected 0: Protected
Protected 0
Refer to User program
“SECURITY
SELECTION”.
6 Inhibited to use 0
7 0
8 0
S
W
2
1 Inhibited to use 0
2 0
3 0
4 0
5 Remote selection
number setup
Binary input
5
0 Refer to User program
“REMOTE
RECEPTION #”.
When a value outside
the set range is set,
the initial value is set.
6 Bit No.
Set range
5678
0 to 9
1
7
0
8
1
S
W
3
1 Density default setup Bit No. 1 2 3 4 5
Medium
0 When a value outside
the set range is set,
the initial value is set.
2 Light 1 0 0 0 0 0
3 Medium 00100 1
4 Dark 00001 0
5 0
6 Inhibited to use 0
7 Size specification Bit No. 7 8
Conforms to the
machine
information.
0
When set to
conformity to the
machine information,
if machine information
is uncertain, set to
centimeter size.
Centimeter size 0 0
Inch size 1 0
8 Conforms to the machine
information.
01
1
Conforms to the machine
information.
11
S
W
4
1 Recall interval in
communication error
Binary input
1min
0 Refer to User program
“RECALL INTERVAL
(LINE ERROR)”.
When a value outside
the set range is set,
the initial value is set.
2 Bit No.
Set range
1234
1 to 15min
0: Recall immediately after
cutting the line
0
3
0
4
1
5 Recall interval in busy Binary input
3min
0
Refer to User program
“
RECALL INTERVAL
(BUSY)”.
When a value outside
the set range is set,
the initial value is set.
6 Bit No.
Set range
5678
1 to 15min
0
7
1
8
1