Service manual

AL-1661CS TEST COMMAND, FAX SOFT SWITCH, TROUBLE CODES 10 - 38
5. FAX soft switch setting change quick reference table
Large item Middle item Switch content Key operator Soft SW No. Usage
Dialing Remote machine call
disable
Pause time None SW 5-5 – 8 When dialing disable/when error dialing
Dial call signal User program SW 48-1, 2 When dialing disable
DTMF-related item None SW 51-1 – 5 When dialing disable in PBX (private branch
exchange/Fax service, etc.)
None SW 53-5 – 8 When dialing disable in PBX (private branch
exchange/Fax service, etc.)
None SW 39-4 – 8 When dialing disable in PBX (private branch
exchange/Fax service, etc.)
Pulse (10PPS) None SW 67-1 – 4 When pulse dialing disable
Signal detection Busy tone detection None SW 7-3 When busy tone detection disable
Busy tone detection None SW 51-7, 8 When busy tone error is detected
Dial tone detection None SW 7-2
Redial In case of an error Resend interval User program SW 4-1 – 4 When send errors occur frequently
In case of an error Number of times of resend User program SW 40-1 – 8
When busy Resend interval User program SW 4-5 – 8 Whey busy occurs frequently
When busy Number of times of resend User program SW 41-1 – 8
Arrival (Call-in) When CI detection
disable
CI detection None SW 12-6, 7 No call-in
CI signal OFF detection
time
None SW 55-1 – 7 No call-in
External
telephone
Setting of an external
telephone connected
Yes/No None SW 47-2 When an external telephone is connected
Remote switch
number
Entry of a 2-digit number User program SW 2-5 – 8 When remote switch is erroneously detected
Remote switch
setting
Yes/No User program SW 8-5 When remote switch is erroneously detected
Communication General Send level None SW 15-4 – 8 When the remote machine cannot receive
signals in a proper level.
JBIG mode None SW 17-4, 8 When an error occurs in the JBIG mode
SG3 V34 mode function setup None SW 43-1 When SG3 communication error occurs
frequently
V34 symbol rate None SW43-4 – 6 When SG3 communication error occurs
frequently
Transmission G3/SG3 DIS reception check None SW 6-8 When an error occurs in phase B
Line equalizer None SW 59-5 – 8 Setting is made referring to the distance from the
station when a communication trouble occurs.
SG3 V34 send speed None SW 44-1 – 4 When an error occurs in the SG3 communication.
Manual send V34 None SW 42-8 When an error occurs in the SG3 communication
in FAX service, etc.
G3 Modem send speed None SW 16-1 – 4 To specified/unspecified destination
RTN reception error None SW 52-5 When judged as “OK” though RTN is received
Reception G3/SG3 CSI transmission None SW 6-3
Maximum reception length None SW 7-6 When a document of 1m or longer is received
SG3 V34 reception speed None SW 44-5 – 8 When fall-down occurs frequently in the SG3
communication
G3 Countermeasure against
echo in reception
None SW 6-4 When an error occurs in phase B in reception
Modem speed in reception None SW 16-5, 6 When the line quality is poor and a fall-back or an
error occurs
EYE-Q check only None SW 72-1 Change in the detection method of training error
Reception print Paper selection Automatic reduction print User program SW 24-8 When reduction print is not made
Index Index print setup User program SW 32-6 When an index is attached to the reception data