Specifications
37
Appendix
7
APPENDIX
7
SPECIFICATIONS
Type Digital copying machine, desk-top type
Copy system Dry, electrostatic transfer
Originals Sheets, bound documents
Original size Max. 10" x 14"
Copy sizes 8-1/2" x 14" to 3-1/2" x 5-1/2"
(Feed copy paper lengthwise only.)
Image loss: Max. 5/32" (4 mm) (leading and trailing edges)
Max. 1/8" (3 mm) (either of the other edges)
Copy speed 10 copies/min.
Continuous copying Max. 99 copies; subtractive counter
First-copy time 9.6 sec. (normal copying mode)
16.0 sec. or less (copying from preheat mode)
23.0 sec. or less (copying from auto power shut-off mode)
23.0 sec. or less (copying immediately after power on)
Copy ratio Variable: 50% to 200% in 1% increments (total 151 steps)
Fixed: 50%, 64%, 78%, 100%, 129%, 200%
Exposure system Moving optical source, slit exposure (stationary platen) with
automatic exposure
Copy paper feed One paper tray with automatic feed (250 sheets); one single-
sheet manual bypass
Fusing system Heat rollers
Development system Magnetic brush development
Light source Xenon lamp
Resolution Scan: 400 dpi Output: 600 dpi
Gradation Scan: 256 levels Output: 2 levels
Memory AL-1000: N/A
AL-1010: 6MB
Power supply AC 120V (±10%), 60 Hz (±2%)
Power consumption 1,000 W
Overall dimensions 23.9" (W) x 17.5" (D) (607 mm (W) x 445 mm (D))
Weight Approx. 39.7 lbs. (18 kg), TD and drum cartridges included
Copier dimensions 20.4" (W) x 17.5" (D) x 11.5" (H)
(518 mm (W) x 445 mm (D) x 293 mm (H))
Operating conditions Temperature: 50°F to 86°F (10°C to 30°C)
Humidity: 20% to 85%
Noise level Sound Power Level LWA (1B=10dB)
Copying: 6.6 [B (A)], Standby: Background noise level
Sound Pressure Level LPA (bystander positions)
Copying: 40 [dB (A)], Standby: Background noise level
Noise emission measurement in accordance with ISO 7779.
First-copy time may differ depending on operating conditions, such as power-supply voltage
and room temperature.
As a part of our policy of continuous improvement, SHARP reserves the right
to make design and specification changes for product improvement without
prior notice. The performance specification figures indicated are nominal values
of production units. There may be some deviation from these values in individual
units.