Service manual

Main code Main code Contents
26 20 Rear edge void setting
(Operation/Procedure)
1. When this simulation is executed, the currently set code number of rear edge void setting is displayed.
2. Enter the code number of rear edge void setting and press the START key, and the setting will be changed.
Code number Rear edge void setting
0 Rear edge void allowed
1 Rear edge void not allowed
30 CE mark application control ON/OFF setting
(Operation/Procedure)
1. When this simulation is executed, the currently set code number of CE mark application is displayed.
2. Enter the code number of CE mark application and press the START key, and the setting will be changed.
Code number CE mark application setting
0 CE mark application control OFF
1 CE mark application control ON
38 Drum life over stop cancel
(Operation/Procedure)
1. When this simulation is executed, the currently set code number is displayed.
2. Enter the code number and press the START key, and the setting will be changed.
Code number Setting
0 Stop at drum life over
1 Stop cancel at drum life over
39 Memory capacity setting
(Operation/Procedure)
1. When this simulation is executed, the currently set code number is displayed.
2. Enter the code number and press the START key, and the setting will be changed.
Code number Setting
0No memory
14Mbyte
26Mbyte
40 Polygon motor OFF time setting
(Operation/Procedure)
1. When this simulation is executed, the currently set code number is displayed.
2. Enter the code number and press the START key, and the setting will be changed.
Code number Setting
00 sec
1 30 sec
2 60 sec
3 90 sec
42 Transfer ON timing control (Setting the time to transfer ON)
(Operation / Procedure)
1.When this simulation is executed, the currently set code number is displayed.
2.Enter the code number and press the START key, and the setting will be changed. (For any number different
from the following ones, the default time is automatically set.)
Code number Setting
0 Default (330 msec)
1 -40msec
2 -30msec
3 -20msec
4 -10msec
5 Default (330 msec)
6 +10msec
7 +20msec
8 +30msec
9 +40msec
AL-1000/1010