User Manual

40
APPENDIX
This chapter shows specifications of the printer, supplies, and how to store the supplies.
SPECIFICATIONS OF THE PRINTER
*1
When printing SHARP original data with draft mode.
*2
For the Bypass Tray, the maximum paper size is 5-sheeted A4/8.5"x11" banner.
*3
Holds up to total thickness of 15mm paper stack.
*4
Holds up to total thickness of 5mm paper stack.
*5
With 75
g/m
2
(20lbs.) plain paper.
*6
When using 20.3cm x 25.4cm (8"x 10") size paper at 5% image area in normal usage.
Name AJ-2100
Type On demand, thermal inkjet type
Resolution Max. 1200dpi x 1200dpi
Printing speed
*1
Monochrome 8.0ppm
Colour 8.0ppm
Paper
Width Max. 215.9mm (8.5") Min. 76.2mm (3")
Length
*2
Max. 355.6mm (14") Min. 127mm (5")
Void area
Min.
Top 3mm, Bottom 3mm,
Left 3mm, Right 3mm
Recommendation
Top 19mm, Bottom 19mm,
Left 10mm, Right 10mm
Print description language Host based printing system
Interface
IEEE1284-compliant bi-directional parallel interface
USB interface (B type)
Paper tray
capacity
Paper tray
*3
Max. 150 sheets of plain paper
*5
Output tray
*4
Max. 50 sheets of plain paper
*5
Bypass tray 1 sheet
Ink life
*6
350 sheets/colour
External dimensions (W x D x H) 440mm x 358mm x 191mm (17.3" x 14.1" x 7.5")
Weight 6.5
kg
(14.3lbs.)
Power supply AC 100V-240V (±10%), 50Hz/60Hz (±10%)
Power
consumption
Idle 9.5W
Printing Max. 45.0W
Operation
condition
Temperature 10°C - 35°C (50°F - 95°F)
Relative humidity 20% - 85%
Storage condition
Temperature -25°C - 40°C (-13°F - 104°F)
Relative humidity 20% - 85%
Noise level
Sound Power Level L
WA
(1B=10dB)
Printing: 6.3[B], Print mode: Sharp Special,
Standby: Background noise level
Sound Pressure Level L
PA
(bystander positions)
Printing: 47[dB(A)], Print mode: Normal,
Standby: Background noise level
Noise emission measurement in accordance with ISO 7779.
As a part of our policy of continuous improvement, SHARP reserves the right to make
design and specification changes for product improvement without prior notice. The
performance specification figures indicated are nominal values of production units.
There may be some deviations from these values in individual units.