Specifications

MX-3610N SIMULATION 5 – 83
<Use example>
(*1)
Make multi copy of 10 sheets. If the density of 10th sheet is greater than that of the first sheet, decrease the set value.
Make multi copy of 10 sheets. If the density of 10th sheet is smaller than that of the first sheet, increase the set value.
When the set value is 0 (Default), the correction level does not work.
44-43
Purpose
Data display
Function (Purpose)
Used to display the identification informa-
tion of the developing unit.
Section
Developing system
Operation/Procedure
The identification number and the identification signal level of the
developing unit are displayed.
* The developing unit is identified by the combination of items E, F, G, H and items I, J, K, and L.
Item/Display Default value
Black CMY Black CMY Variable range
Current DV Bias voltage Low speed mode
Heavy paper mode
less than 300 [v] A A 0 0 0-5
(*1)
300 [v] or more, less than 450 [v] B B 0 0
450 [v] or more C C 0 0
Middle speed mode less than 300 [v] D D 0 0
300 [v] or more, less than 450 [v] E E 0 0
450 [v] or more F F 0 0
High speed mode
Monochrome mode
less than 300 [v] G - 0 -
300 [v] or more, less than 450 [v] H - 0 -
450 [v] or more I - 0 -
Time (T) from termination of
continuous outputs to start of
the next output operation
Low speed mode
Heavy paper mode
Less than 10 [sec] & after process control JOB J G 4 4 1-12
10 [sec] or more, less than 60 [sec] K H 3 3
60 [sec] or more, less than 240 [sec] L I 1 1
240 [sec] or more M J 1 1
Middle speed mode Less than 10 [sec] & after process control JOB N K 4 4
10 [sec] or more, less than 60 [sec] O L 3 3
60 [sec] or more, less than 240 [sec] P M 1 1
240 [sec] or more Q N 1 1
High speed mode
Monochrome mode
Less than 10 [sec] & after process control JOB R - 4 -
10 [sec] or more, less than 60 [sec] S - 3 -
60 [sec] or more, less than 240 [sec] T - 1 -
240 [sec] or more U - 1 -
Item/Display Content Display range NOTE
A DVCH KIND K K developing unit identification number 1 - 9 The model identification number of the developing unit which
is backed up in the EEPROM of the machine.
B DVCH KIND C C developing unit identification number 1 - 9
C DVCH KIND M M developing unit identification number 1 - 9
D DVCH KIND Y Y developing unit identification number 1 - 9
E DV_TYP_SEL_K K developing unit identification detection 0 - 1 0 = High (Open)
1 = Low (GND)
F DV_TYP_SEL_C C developing unit identification detection 0 - 1
G DV_TYP_SEL_M M developing unit identification detection 0 - 1
H DV_TYP_SEL_Y Y developing unit identification detection 0 - 1
I DVCH_AD_K K developing unit identification AD value 0 - 255 AD value of the developing unit identification voltage
J DVCH_AD_C C developing unit identification AD value 0 - 255
K DVCH_AD_M M developing unit identification AD value 0 - 255