Specifications

MX-3610N SIMULATION 5 – 80
Mode Item/Display Content Setting range
Default
value
Process control
Enable/Disable
setting
A INITIAL YES When warm-up after clearing the counter
of the OPC drum and the developer unit
Enable 0 - 1 0 0
NO Disable 1
B SW ON When supplying the power (when
canceling power shut-off)
Color process control
Enable
0 - 3 0 3
Process control Disable 1
BK process control Enable 2
Pixel count judgment 3
C TIME After passing the specified time from
leaving READY continuously (Time can be
changed by INTERVAL TIME)
Color process control
Enable
0 - 3 0 3
Process control Disable 1
BK process control Enable 2
Pixel count judgment 3
D HUM_LIMIT HUM judgment is made when turning ON
the power and after passing INTERVAL
TIME.
Color process control
Enable
0 - 2 0 0
Process control Disable 1
BK process control Enable 2
E HUM The temperature and humidity inside the
machine are monitored only during a job at
the interval set by the item of HUM HOUR.
When the changes in the temperature and
the humidity are greater than the specified
level (the set value of item HUM DIF) in
comparison with the previous process
control.
Color process control
Enable
0 - 2 0 0
Process control Disable 1
BK process control Enable 2
F REV1 YES When the accumulated traveling distance
of K or M OPC drum unit reaches the
specified level after turning ON the power.
Enable 0 - 1 0 0
NO Inhibit 1
G REV2_BK YES When the accumulated traveling distance
of K OPC drum unit reaches the specified
level from execution of the previous
density correction.
Enable 0 - 1 0 0
NO Inhibit 1
H REV2_CL YES When the accumulated traveling distance
of M OPC drum unit reaches the specified
level from execution of the previous
density correction.
Enable 0 - 1 0 0
NO Inhibit 1
IREFRESH
MODE
YES Select of YES/NO of the manual process
control key with key operation
Key operation display 0 - 1 0 1
NO Key operation NO display 1
Setting of the
execution
conditions of
the process
control
J DAY When there is no color job from when the
previous color process control was
performed to when the number of days set
by this item setting, perform the process
control when executing the next warming
up.
0: Disable of the specified
days judgment
0 - 999 0 1
1 - 999: 1 - 999 days
passing
999
K HI-COV Setting of the execution conditions of the
process control for the print ratio
The process control is
performed by considering
the average print ratio of
every 10 pages as the
judgment criteria.
0 - 2 0 0
Print ratio judgment inhibit
(The process control for
the target of print ratio is
not performed.)
1
The process control is
performed by considering
the average print ratio of
30 pages as the judgment
criteria in a continuous
print job of 30 or more
pages.