Specifications

MX-3610N SIMULATION 5 – 75
44-4
Purpose
Setting
Function (Purpose)
Used to set the conditions of the high den-
sity process control operation.
Section
Process
Operation/Procedure
1) Select an item to be set with scroll keys.
2) Enter the set value with 10-key.
3) Press [OK] key.
Set the items to the default values unless a change is specially
required.
44-6
Purpose
Adjustment
Function (Purpose)
Used to execute the high density process
control forcibly.
Section
Process
Operation/Procedure
Press [EXECUTE] key.
In case of a normal completion, the result is saved.
In case of an abnormal completion, "ERROR" is displayed.
(Refer to the table below.)
In case of an ERROR, the previous correction data are saved.
REGIST X REG_F
PATCH (Y)
Toner patch
detection level F
(Y) in the
registration
adjustment
0 - 255 0
YREG_R
PATCH (K)
Toner patch
detection level R
(K) in the
registration
adjustment
0 - 255 0
ZREG_R
PATCH (C)
Toner patch
detection level R
(C) in the
registration
adjustment
0 - 255 0
AA REG_R
PATCH (M)
Toner patch
detection level R
(M) in the
registration
adjustment
0 - 255 0
AB REG_R
PATCH (Y)
Toner patch
detection level R
(Y) in the
registration
adjustment
0 - 255 0
Error name Error content
Black sensor
adjustment
abnormality
PCS_K LED ADJ error
The target is not reached by 3 times of
adjustments.
Color sensor
adjustment
abnormality
PCS_CL LED ADJ error
The target is not reached by 3 times of
adjustments.
Substrate scan
abnormality
PCS_K GRND error
The difference between the max. value and the
min. value of the substrate detection level is
greater than the specified value when the transfer
belt rotates one turn.
Registration sensor
F adjustment
abnormality
REG_F LED ADJ error
The target is not reached by 3 times of
adjustments.
Registration sensor
R adjustment
abnormality
REG_R LED ADJ error
The target is not reached by 3 times of
adjustments.
Registration
substrate F scan
abnormality
REG_F GRND error
The difference between the max. value and the
min. value of the substrate detection level is
greater than the specified value when the transfer
belt rotates one turn.
Registration
substrate R scan
abnormality
REG_R GRND error
The difference between the max. value and the
min. value of the substrate detection level is
greater than the specified value when the transfer
belt rotates one turn.
Classifi-
cation
Item/Display Content
Setting
range
Default
value
Item/Display Content
Setting
range
Default
value
A PCS_CL TARGET Color image sensor
adjustment target value
1 - 255 98
B PCS_K TARGET Black image sensor
adjustment target value
1 - 255 208
C LED_CL OUTPUT Color image sensor light
emitting start level
1 - 255 21
D LED_K OUTPUT Black image sensor light
emitting start level
1 - 255 21
E PCS ADJSTMENT
LIMIT
Color image sensor
adjustment error
allowance level
1 - 255 4
F BELT GROUND
DIF
Transfer belt one-turn
substrate detection level
difference allowance
level
1 - 255 1
GBIAS_CL
STANDARD DIF
Developing bias (for
color) reference
correction voltage
0 - 255 60
H BIAS_BK
STANDARD DIF
Developing bias (for
black) reference
correction voltage
0 - 255 0
I BIAS PATCH
INTERVAL
Toner patch making
developing bias interval
1 - 255 60
J Y_PAT TARGET ID Process control target
density level (yellow)
1 - 255 111
K M_PAT TARGET ID Process control target
density level (magenta)
1 - 255 135
L C_PAT TARGET ID Process control target
density level (cyan)
1 - 255 128
M K_PAT TARGET ID Process control target
density level (black)
1 - 255 45
N HV BK_GROUND
LIMIT
Black image sensor
adjustment error
allowance level
1 - 255 60
Result display Content description
COMPLETE Normal complete
ERROR Abnormal end
INTERRUPTION Forcible interruption
Details of error display Content description
CL_SEN_ADJ_ERR Color image sensor adjustment abnormality
BK_SEN_ADJ_ERR Black image sensor adjustment abnormality
K_HV_ERR K high density process control abnormality
C_HV_ERR C high density process control abnormality
M_HV_ERR M high density process control abnormality
Y_HV _ERR Y high density process control abnormality
TIMEOUT_ERR Time out