Specifications

MX-3610N SIMULATION 5 – 74
44-2
Purpose
Adjustment/Setup
Function (Purpose)
Used to adjust the sensitivity of the image
density sensor (registration sensor).
Section
Process
Operation/Procedure
When [EXECUTE] key is pressed, the adjustment is executed auto-
matically.
After completion of the adjustment, the adjustment result is dis-
played.
If the adjustment is not executed normally, "ERROR" is displayed.
TN_EMP Setting of Enable/
Disable of the toner
falling distance
detection control
Normal
(Disable:
1: NO)
Reverse
(Enable:
0: YES)
Enable
TN_EMP_
INT
Setting of Enable/
Disable of the toner
falling distance
detection control of job
interruption
Enable
TN_EMP_
NEW
Setting of Enable/
Disable of the new
toner cartridge falling
distance detection
control
Enable
TN_PIX_
TBL
Setting of Enable/
Disable of execution of
revision of the yield
count conversion table
for the toner supply
control in the halftone
process control
Enable
AR_AUTO Auto registration
adjustment Enable/
Disable setting
Enable
AR_ERROR Auto registration
adjustment execution
error check Enable/
Disable setting
Enable
DM_PHASE Drum phase fitting
Enable/Disable setting
Enable
PRT_HT Halftone process
control printer
correction feedback
Enable/Disable setting
Enable
PTC_ENV PTC environment
correction Enable/
Disable setting
Enable Enable:
Correc-
tion ON
Classifi-
cation
Item/Display Content
Setting
range
Default
value
PROCON A PCS_CL
LED ADJ
Color image sensor
light emitting
quantity
adjustment value
1 - 255 21
BPCS_K
LED ADJ
Black image
sensor light
emitting quantity
adjustment value
1 - 255 21
CPCS_CL
DARK
Dark voltage of
color image sensor
0 - 255 0
DPCS_K
DARK
Dark voltage of
black image sensor
0 - 255 0
EPCS_K
GRND
Transfer belt
substrate detection
level when the item
B adjustment is
completed
0 - 255 0
Item/
Display
Content
Setting
range
Default
value
NOTE
PROCON F PCS_K
BELT MAX
Transfer belt
substrate input
max. value
0 - 255 0
GPCS_K
BELT MIN
Transfer belt
substrate input
min. value
0 - 255 0
HPCS_K
BELT DIF
Transfer belt
substrate input
difference (Item E -
Item F)
0 - 255 0
REGIST I REG_F
LED ADJ
Registration sensor
light emitting
quantity
adjustment value F
1 - 255 56
JREG_F
DARK
Registration sensor
dark voltage F
0 - 255 0
KREG_F
GRND
Transfer belt
substrate detection
level when the item
I adjustment is
completed
0 - 255 0
LREG_R
LED ADJ
Registration sensor
light emitting
quantity
adjustment value R
1 - 255 56
MREG_R
DARK
Registration sensor
dark voltage R
0 - 255 0
NREG_R
GRND
Transfer belt
substrate detection
level when the item
J adjustment is
completed
0 - 256 0
OREG_F
BELT MAX
Transfer belt
substrate detection
level max. value (F
side)
0 - 255 0
PREG_F
BELT MIN
Transfer belt
substrate detection
level min. value (F
side)
0 - 255 0
QREG_F
BELT DIF
Transfer belt
substrate detection
level difference
(Item O - Item P)
0 - 255 0
RREG_R
BELT MAX
Transfer belt
substrate detection
level max. value (R
side)
0 - 255 0
SREG_R
BELT MIN
Transfer belt
substrate detection
level min. value (R
side)
0 - 255 0
TREG_R
BELT DIF
Transfer belt
substrate detection
level difference
(Item R - Item S)
0 - 255 0
UREG_F
PATCH (K)
Toner patch
detection level F
(K) in the
registration
adjustment
0 - 255 0
VREG_F
PATCH (C)
Toner patch
detection level F
(C) in the
registration
adjustment
0 - 255 0
WREG_F
PATCH (M)
Toner patch
detection level F
(M) in the
registration
adjustment
0 - 255 0
Classifi-
cation
Item/Display Content
Setting
range
Default
value