Specifications

MX-3610N SIMULATION 5 – 73
43-31
Purpose
Adjustment/Setup
Function (Purpose)
Used to check the operation of the fusing
web cleaning. (36cpm machine)
Section
Fusing
Operation/Procedure
1) Press [EXECUTE] key.
Cleaning the fusing web is performed.
2) When cleaning the fusing web is completed, "COMPLETE" is
displayed.
The set value may be changed for a design change or an individual
arrangement. Except for the above cases, however, the set value
must not be changed. If it is changed, a trouble may be occur.
43-32
Purpose
Adjustment/Setup
Function (Purpose)
Used to set various items related to the
forcible operation of web cleaning when job
end. (36cpm machine)
Section
Fusing
Operation/Procedure
1) Select an item to be set with the scroll key.
2) Enter the set value with 10-key.
3) Press [OK] key.
The set value in step 2) is saved.
The set value may be changed for a design change or an individual
arrangement. Except for the above cases, however, the set value
must not be changed. If it is changed, a trouble may be occur.
44
44-1
Purpose
Setting
Function (Purpose)
Used to set each correction operation func-
tion in the image forming (process) section.
Section
Image process (Photoconductor/Develop-
ing/Transfer/Cleaning)
Operation/Procedure
1) Select an item to be set with the touch panel.
(The selected item is highlighted.)
2) Press [EXECUTE] key. (The set value is saved.)
Set the items to the default values unless a change is specially
required.
Fusing web unit
installation
detection state
Operation Remarks
Fusing web unit not
installed
Does not operate * During this operation, the
fusing web cleaning feed
counter is counted up.
Fusing web unit
installed
Operates for the
specified time.
Item/Display Item
Setting
range
Default
value
A JOB END
COMP ACT
CHECK
Fusing web motor
forcible operation
condition when job end
Enable 0 - 1 0 1
Disable 1
B JOB END
COMP ACT
INTERVAL
Interval of the print quantity of
compulsory action of the fusing
web motor at job end
1 - 200 100
C JOB END
COMP ACT
CNT
Number of forcible operations of
the fusing web motor when job
end
1 - 5 1
Item/
Display
Content
Setting
range
Default
value
NOTE
HV Normal operation high
density process control
Enable/Disable setting
Normal
(Disable:
1: NO)
Reverse
(Enable:
0: YES)
Enable
HT Normal operation
halftone process control
Enable/Disable setting
Enable
TC Transfer output
correction Enable/
Disable setting
Enable
MD VG Membrane decrease
grid voltage correction
Enable/Disable setting
Enable
MD LD Membrane laser power
voltage correction
Enable/Disable setting
Disable
MD EV Membrane decrease
environment grid
voltage correction
Enable/Disable setting
Enable
MD DL Membrane decrease
discharge light quantity
correction Enable/
Disable setting
Enable
MD DL EV Membrane decrease
environment discharge
light quantity correction
Enable/Disable setting
Disable
TN_PIX_
SUP
Setting of Enable/
Disable of toner supply
control for the yield
count
Enable
TN_FB Setting of Enable/
Disable of the toner
density correction for
the process control
result
Enable
TN_INT Setting of Enable/
Disable of toner
compulsory supply
correction for the
development traveling
distance
Enable
TN_RECV Setting of Enable/
Disable of the toner
density recovery
operation
Enable
TN_ADJ Setting of Enable/
Disable of the toner
sensor control voltage
adjustment in the
process control
Enable