Specifications
MX-3610N SIMULATION 5 – 49
Code descriptions
List of destination groups
23cpm machine
AS JOBEND_FUMON_TIME Fusing motor after rotation time after completion of
a job (Excluding heavy paper, OPH, and envelopes)
0 - 255555555
AT HL_UM_JOB_SET_TMP_B
W
Job enable temperature (B/W) when the upper roller
temperature is lower than alpha C
70 - 230 145 170 170 160 175 175
Item/Display Content
Setting
range
Default value (SW-A) Default value (SW-B)
Group
A
Group
B
Group
C
Group
A
Group
B
Group
C
TH_UM Fusing thermistor main (Front surface of paper) HL_UM Heater lamp main (Heat roller for front surface of paper)
TH_LM Fusing thermistor main (Back surface of paper) HL_LM Heater lamp main (Heat roller for front surface of paper)
TH_US Fusing thermistor sub (Front surface of paper) HL_US Heater lamp sub (Heat roller for front surface of paper)
SW-A Setting value when plain paper is selected in the system setting/device setting/fusing control setting.
SW-B Set value when heavy paper is selected in the system setting/device setting/fusing control setting.
The set value displayed in this simulation differs depending on plain paper or heavy paper which is selected in the system setting/device setting/fusing
control setting.
(Example) When plain paper is selected in the system setting/device setting/fusing control setting, the value of SW-A is displayed.
Group Destination
Group AJAPAN––––
Group B U. S. A CANADA INCH – –
Group C EUROPE U. K AUS. AB_B CHINA
Item/Display Content
Setting
range
Default value (SW-A) Default value (SW-B)
Group
A
Group
B
Group
C
Group
A
Group
B
Group
C
A HL_UM READY Ready standby TH_UM set value 70 - 230 95 110 110 125 115 125
B HL_LM READY Ready standby TH_LM set value 30 - 200 90 105 105 100 115 115
C HL_US READY Ready standby TH_US set value 70 - 230 135 140 140 150 145 150
D HL_UM PLAIN PAPER BW Black-White plain paper TH_UM set value 70 - 230 125 125 135 140 130 145
E HL_LM PLAIN PAPER BW Black-White plain paper TH_LM set value 30 - 200 110 115 115 110 125 125
F HL_US PLAIN PAPER BW Black-White plain paper TH_US set value 70 - 230 135 135 140 150 140 150
G HL_UM PLAIN PAPER CL Color plain paper TH_UM set value 70 - 230 125 130 135 140 135 145
H HL_LM PLAIN PAPER CL Color plain paper TH_LM set value 30 - 200 110 115 115 110 125 125
I HL_US PLAIN PAPER CL Color plain paper TH_US set value 70 - 230 135 140 140 150 145 150
J WARMUP FUMON HL_US T Fusing motor pre-rotation start TH_US set value 30 - 200 30 30 30 30 30 30
K WARMUP FUMOFF Fusing motor previous rotation complete time 0 - 255 20 20 20 20 20 20
L WARM UP END TIME Warm-up complete time 1 - 255 16 16 16 16 16 16
M HL_UM HEAVY PAPER Heavy paper TH_UM set value 70 - 230 170 170 170 170 170 170
N HL_LM HEAVY PAPER Heavy paper TH_LM set value 30 - 200 120 120 120 120 120 120
O HL_US HEAVY PAPER Heavy paper TH_US set value 70 - 230 160 160 160 160 160 160
P HL_UM OHP PAPER OHP-TH_UM set value 70 - 230 175 175 175 175 175 175
Q HL_LM OHP PAPER OHP-TH_LM set value 30 - 200 125 125 125 125 125 125
R HL_US OHP PAPER OHP-TH_US set value 70 - 230 175 175 175 175 175 175
S HL_UM ENV PAPER Envelope TH_UM set value 70 - 230 175 175 175 175 175 175
T HL_LM ENV PAPER Envelope TH_LM set value 30 - 200 125 125 125 125 125 125
U HL_US ENV PAPER Envelope TH_US set value 70 - 230 175 175 175 175 175 175
V HL_UM GLOSS PAPER Glossy paper TH_UM set value 70 - 230 180 180 180 180 180 180
W HL_LM GLOSS PAPER Glossy paper TH_LM set value 30 - 200 120 120 120 120 120 120
X HL_US GLOSS PAPER Glossy paper TH_US set value 70 - 230 180 180 180 180 180 180
Y HL_UM E-STAR Preheating TH_UM set value 30 - 200 85 105 100 85 105 100
Z HL_US E-STAR Preheating TH_US set value 30 - 200 125 135 130 125 135 130
AA HL_UM PRE-JOB Preheat mode restore complete temperature 30 - 200 120 125 130 135 130 140
AB HL_LM E-STAR Preheating TH_LM set value 30 - 200 70 90 90 70 90 90
AC HL_UM HEAVY2 PAPER Heavy paper 2 TH_UM set value 70 - 230 170 170 170 170 170 170
AD HL_LM HEAVY2 PAPER Heavy paper 2 TH_LM set value 30 - 200 120 120 120 120 120 120
AE HL_US HEAVY2 PAPER Heavy paper 2 TH_SU set value 70 - 230 160 160 160 160 160 160
AF HL_UM WARMUP_120L TH_UM set value when Warm-Up at 120C or below 70 - 230 135 145 145 140 140 145
AG HL_LM WARMUP_120L TH_LM set value when Warm-Up at 120C or below 30 - 200 90 105 105 100 115 115
AH HL_US WARMUP_120L TH_US set value when Warm-Up at 120C or below 70 - 230 125 135 135 135 135 145
AI LO_WARMUP_TIME AF - AH applying time
(Timer from completion of Ready)
0 - 255000000
AJ HL_UM WARMUP_120H TH_UM set value when Warm-Up at 120C or
above
70 - 230 135 145 145 140 140 145
AK HL_LM WARMUP_120H TH_LM set value when Warm-Up at 120C or above 30 - 200 90 105 105 100 115 115
AL HL_US WARMUP_120H TH_US set value when Warm-Up at 120C or above 70 - 230 125 135 135 135 135 145
AM HI_WARMUP_TIME AJ - AL applying time
(Timer from completion of Ready)