Specifications

MX-3610N SIMULATION 5 – 48
43
43-1
Purpose
Setting
Function (Purpose)
Used to set the fusing temperature in each
mode.
Section
Operation/Procedure
1) Select an item to be set with scroll keys.
2) Enter the set value with 10-key.
3) Press [OK] key.
The set value in step 2) is saved.
18cpm/20cpm machine
Item/Display Content
Setting
range
Default value (SW-A) Default value (SW-B)
Group
A
Group
B
Group
C
Group
A
Group
B
Group
C
A HL_UM READY Ready standby TH_UM set value 70 - 230 150 175 175 165 180 180
B HL_LM READY Ready standby TH_LM set value 30 - 200 110 110 110 120 120 120
C HL_US READY Ready standby TH_US set value 70 - 230 150 165 165 165 170 170
D HL_UM PLAIN PAPER BW Black-White plain paper TH_UM set value 70 - 230 135 160 160 150 165 165
E HL_LM PLAIN PAPER BW Black-White plain paper TH_LM set value 30 - 200 125 140 140 140 140 140
F HL_US PLAIN PAPER BW Black-White plain paper TH_US set value 70 - 230 135 155 155 150 160 160
G HL_UM PLAIN PAPER CL Color plain paper TH_UM set value 70 - 230 145 170 170 160 175 175
H HL_LM PLAIN PAPER CL Color plain paper TH_LM set value 30 - 200 135 140 140 140 140 140
I HL_US PLAIN PAPER CL Color plain paper TH_US set value 70 - 230 145 160 160 160 165 165
J WARMUP FUMON HL_US T Fusing motor pre-rotation start TH_US set value 30 - 200 135 135 135 135 135 135
K WARMUP FUMOFF Fusing motor previous rotation complete time 0 - 255 30 30 30 30 30 30
L WARM UP END TIME Warm-up complete time 1 - 255 38 38 38 38 38 38
M HL_UM HEAVY PAPER Heavy paper TH_UM set value 70 - 230 170 170 170 170 170 170
N HL_LM HEAVY PAPER Heavy paper TH_LM set value 30 - 200 140 140 140 140 140 140
O HL_US HEAVY PAPER Heavy paper TH_US set value 70 - 230 170 170 170 170 170 170
P HL_UM OHP PAPER OHP-TH_UM set value 70 - 230 175 175 175 175 175 175
Q HL_LM OHP PAPER OHP-TH_LM set value 30 - 200 135 135 135 135 135 135
R HL_US OHP PAPER OHP-TH_US set value 70 - 230 175 175 175 175 175 175
S HL_UM ENV PAPER Envelope TH_UM set value 70 - 230 180 170 170 180 170 170
T HL_LM ENV PAPER Envelope TH_LM set value 30 - 200 145 135 135 145 135 135
U HL_US ENV PAPER Envelope TH_US set value 70 - 230 180 170 170 180 170 170
V HL_UM GLOSS PAPER Glossy paper TH_UM set value 70 - 230 180 180 180 180 180 180
W HL_LM GLOSS PAPER Glossy paper TH_LM set value 30 - 200 140 140 140 140 140 140
X HL_US GLOSS PAPER Glossy paper TH_US set value 70 - 230 180 180 180 180 180 180
Y HL_UM E-STAR Preheating TH_UM set value 30 - 200 125 125 125 125 125 125
Z HL_US E-STAR Preheating TH_US set value 30 - 200 125 125 125 125 125 125
AA HL_UM PRE-JOB Preheat mode restore complete temperature 30 - 200 130 130 130 130 130 130
AB HL_LM E-STAR Preheating TH_LM set value 30 - 200 115 115 115 115 115 115
AC HL_UM HEAVY2 PAPER Heavy paper 2 TH_UM set value 70 - 230 175 175 175 175 175 175
AD HL_LM HEAVY2 PAPER Heavy paper 2 TH_LM set value 30 - 200 140 140 140 140 140 140
AE HL_US HEAVY2 PAPER Heavy paper 2 TH_SU set value 70 - 230 175 175 175 175 175 175
AF HL_UM WARMUP_120L TH_UM set value when Warm-Up at 120C or below 70 - 230 145 170 170 160 175 175
AG HL_LM WARMUP_120L TH_LM set value when Warm-Up at 120C or below 30 - 200 110 110 110 110 110 110
AH HL_US WARMUP_120L TH_US set value when Warm-Up at 120C or below 70 - 230 135 150 150 150 155 155
AI LO_WARMUP_TIME AF - AH applying time
(Timer from completion of Ready)
0 - 255000000
AJ HL_UM WARMUP_120H TH_UM set value when Warm-Up at 120C or
above
70 - 230 145 170 170 160 175 175
AK HL_LM WARMUP_120H TH_LM set value when Warm-Up at 120C or above 30 - 200 110 110 110 110 110 110
AL HL_US WARMUP_120H TH_US set value when Warm-Up at 120C or above 70 - 230 135 150 150 150 155 155
AM HI_WARMUP_TIME AJ - AL applying time
(Timer from completion of Ready)
0 - 255000000
AN HI_WU_FM_ON_TMP FM prior rotation start TH_US when Warm-Up at
alpha C or above
30 - 200 105 105 105 105 105 105
AO HI_WU_END_TIME Warm-Up completion time when Warm-Up at alpha
C or above
0 - 255383838383838
AP HI_WU_JOB_SET_TMP Job enable TH_UM temperature when Warm-Up at
alpha C or above
70 - 230 145 170 170 160 175 175
AQ HI_WARMUP_BORDER Threshold value alpha to which SIM43-1-AN - AP is
applied
1 - 119707070707070
AR LO_WU_JOB_SET_TMP Job enable TH_UM temperature when Warm-Up at
alpha C or below
70 - 230 145 170 170 160 175 175