Specifications

MX-3610N SIMULATION 5 – 132
62-20
Purpose
Operation test/check
Function (Purpose)
Used to check the operation of the mirror-
ing hard disk. (26cpm/36cpm/31cpm(A)
machine)
Section
Mirroring hard disk
Operation/Procedure
Enter the simulation mode, and the operation status of the HDD is
displayed.
The status display is renewed in every second.
63
63-1
Purpose
Adjustment/Setting/Operation data check
Function (Purpose)
Used to display the shading correction
result.
Section
Scanner
Operation/Procedure
1) Select a target color to display with [R] [G] [B] on the touch
panel.
[RSPF]
63-2
Purpose
Adjustment
Function (Purpose)
Used to perform shading.
Section
Operation/Procedure
1) (When RSPF model)
Press [EXECUTE] key.
Used to perform shading.
When the operation is completed, [EXECUTE] key returns to the
normal display.
63-3
Purpose
Adjustment
Function (Purpose)
Used to perform scanner (CCD) color bal-
ance and gamma auto adjustment.
Section
Scanner
Operation/Procedure
1) Place the SIT chart (UKOG-0280FCZZ or UKOG-0280FCZ1)
on the reference position of the left rear frame side of the doc-
ument table.
2) Press [EXECUTE] key.
The scanner (CCD) color balance automatic adjustment is per-
formed.
When the operation is completed, [EXECUTE] key returns to the
normal display.
After completion of the operation, press [RESULT] key, and the
adjustment data are displayed. At that time, the target color of data
display can be selected with [R] [G] [B] key.
Display Content description
OK Normal operation
NONE Not connected
REBUILDING Data rebuilding
ERROR Error occurrence
TROUBLE Trouble
Item/
Display
Content NOTE
GAIN ODD Gain adjustment value
(odd number)
GAIN EVEN Gain adjustment value
(Even number)
OFFSET
ODD
Offset value
(odd number)
OFFSET
EVEN
Offset value
(even number)
SMP AVE
ODD
Reference plate
sampling average
value (ODD)
SMP AVE
EVEN
Reference plate
sampling average
value (EVEN)
TARGET
VALUE
Target value
BLACK
LEVEL
Black output level
ERROR
CODE
Error code
(0, 1-14)
(for debug)
0 No error
1 Loop number over
2 The target value is under
the specified value.
3 The gain set value is
negative.
4 END is not asserted.
(Gain adjustment)
5 (reserve)
6 Underflow
7 Black shading error
8 Other error
9 END is not asserted.
(White shading)
10 END is not asserted.
(Black shading)
11 END is not asserted.
(Light quantity correction)
12 END is not asserted.
(Scan)
13 Register check error.
(When booting/
Before gain)
14 Register check error.
(Before light quantity
correction)
RSPF
WHITE
LEVEL 1ST
First scan
RSPF white reference
level
RSPF
WHITE
LEVEL 2ND
Second scan
RSPF white reference
level
Item/
Display
Content NOTE