OPERATION MANUAL INSTALLATION MANUAL AH-PN10, 10GY AH-L10 AH-PN13, 13GY AH-L13 AH-PN19, AH-PN24 INDOOR UNIT AH-PN10 AH-PN10-GY AH-PN13 AH-PN13-GY AH-PN19 AH-PN24 AH-L10 AH-L13 OUTDOOR UNIT AU-PN10 AU-PN10 AU-PN13 AU-PN13 AU-PN19 AU-PN24 AU-L10 AU-L13 CONTENTS Page IMPORTANT SAFETY INSTRUCTIONS 1 PART NAMES 2 USING THE REMOTE CONTROL 5 AUXILIARY MODE 5 TIPS ON SAVING ENERGY 5 BASIC OPERATION 6 ADJUSTING THE AIR FLOW DIRECTION 7 POWERFUL JET OPERATION 7 GENTLE COOL AIR 8 PLASMACLUSTE
OM_AH-PN10 13GY_EN.
ENGLISH Please read this manual carefully before using the product. This manual should be kept in a safe place for handy reference. CAUTIONS IMPORTANT SAFETY INSTRUCTIONS WARNINGS • Do not pull or deform the power supply cord. Pulling and misuse of the power supply cord can result in damage to the unit and cause electrical shock. • Be careful not to expose your body directly to the outlet air for a long time. It may affect your physical conditions.
PART NAMES INDOOR UNIT 12 9 1 Inlet (Air) 2 3 2 Open Panel 4 4 AUX Button 5 5 Receiver Window 6 6 Vertical Airflow Louvre 7 8 7 Horizontal Airflow Louvre 3 Air Filter 8 Outlet (Air) 9 9 OPERATION Lamp (red ) 10 10 TIMER Lamp (orange ) 11 11 POWERFUL JET Lamp (green ) 10 11 AH-PN10, AH-PN10-GY AH-PN13, AH-PN13-GY 1 12 PLASMACLUSTER Lamp (blue ) AH-L10 AH-L13 OUTDOOR UNIT AU-PN10 AU-PN13 AU-L10 AU-L13 13 13 Inlet (Air) 14 14 Refrigerant Pipe and Interconnecting Cord 15 Drainage Hose
INDOOR UNIT 1 1 Inlet (Air) 2 3 2 Open Panel 4 4 AUX Button 5 5 Receiver Window 6 6 Power Supply Cord 7 8 9 7 Vertical Airflow Louvre 3 Air Filter ENG- 8 Horizontal Airflow Louvre 9 Outlet (Air) 10 10 PLASMACLUSTER Lamp (blue ) 11 12 11 OPERATION Lamp (red OUTDOOR UNIT AU-PN19 14 15 16 ) ) 13 12 TIMER Lamp (orange 13 POWERFUL JET Lamp AH-PN19, AH-PN24 (blue ) 17 AU-PN24 14 15 16 14 Inlet (Air) 15 Refrigerant Pipe and Interconnecting Cord 16 Drainage Hose 17 Outlet (Air) 17 NOTE:
PART NAMES REMOTE CONTROL 1 1 TRANSMITTER 2 DISPLAY 3 ON/OFF Button 4 THERMOSTAT Button 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 5 DISPLAY Button 6 ONE-HOUR OFF TIMER Button 7 PLASMACLUSTER Button (AH-PN10, AH-PN10-GY AH-PN13, AH-PN13-GY AH-PN19, AH-PN24 ONLY) 8 TIMER ON Button 9 MODE Button 10 TIMER OFF Button 11 FAN Button 12 TIMER CANCEL Button 13 SWING Button 14 Reset Button 15 POWERFUL JET Button 16 GENTLE COOL AIR Button 17 MODE Symbols : AUTO 21 22 19 20 : DRY 18 POWERFUL JET Symbol DISPLAY 17 1
AUXILIARY MODE USING THE REMOTE CONTROL LOADING BATTERIES Use this mode when the remote control is not available. the battery cover. 1 Remove Insert two batteries. (AAA(R03)) 2 + the battery cover. 3 Reinstall Press the RESET button using a 4 thin stick. TO TURN ON Press the AUX button. Make sure the ( ) and ( ) polarities are correctly aligned. • The fan speed and temperature setting are set to AUTO. ENG- • The red OPERATION lamp ( ) will light and the unit will start operating in the AUTO mode.
BASIC OPERATION Press the MODE button to select the 1 operation mode. AUTO 2 3 1 4 COOL DRY Press the ON/OFF button to start 2 operation. • The red OPERATION lamp ( ) will light up. TO TURN OFF Press the ON/OFF button again. • The red OPERATION lamp ( ) will turn off. Press the THERMOSTAT button to 3 set the desired temperature. (AUTO/DRY mode) The temperature can be changed up to ±2 °C the automatically set of temperature. (COOL mode) The temperature setting range: 16-30°C.
ADJUSTING THE AIR FLOW DIRECTION POWERFUL JET OPERATION The air conditioner works at the maximum power and optimum louvre direction to makes the room cool rapidly. VERTICAL AIR FLOW DIRECTION 1 Press the SWING button. the SWING button again 2 toPress stop the desired position. • The vertical airflow louvre will swing. During operation, press the JET button. 1 POWERFUL • The green POWERFUL JET lamp ( will light up. • The vertical airflow louvre will be set obliquely downward.
GENTLE COOL AIR PLASMACLUSTER OPERATION The vertical airflow louvre is set obliquely upward to deliver cool air to the ceiling in order to avoid direct airflow. (AH-PN10, AH-PN10-GY AH-PN13, AH-PN13-GY AH-PN19, AH-PN24 ONLY) During operation, press the COOL AIR button. 1 GENTLE Plasmacluster ions released into the room will reduce some airborne mold. • The remote control will display “ ”. During operation, press the 1 PLASMACLUSTER button. • The remote control will display “ ”.
TIMER OPERATION TIMER ON TIMER OFF the TIMER ON button and Press the TIMER OFF button and 1 Press set the time as desired. 1 set the time as desired. 0.5h 1.0h 1.5h 10h 11h 0.5h 12h 1.0h 1.5h 10h 11h 12h • The orange TIMER lamp ( ) will light up. • The time setting will count down to show the remaining time. TO CANCEL TO CANCEL Press the CANCEL button. Press the CANCEL button. • The orange TIMER lamp ( ENG- • The orange TIMER lamp ( ) will light up.
ONE-HOUR OFF TIMER DISPLAY BUTTON When the ONE-HOUR OFF TIMER is set, the unit will automatically turn off after one hour. Press the ONE-HOUR OFF TIMER 1 button. • The remote control will displays “ • The orange TIMER lamp ( Use when the lamps on the unit are too bright. (The red OPERATION lamp and the orange TIMER lamp cannot be turned off.) During operation, press the 1 DISPLAY button. ”. • The blue PLASMACLUSTER lamp ( ) will light up. TO CANCEL TO LIGHT UP Press the CANCEL button.
MAINTENANCE MAINTENANCE AFTER AIR CONDITIONER SEASON Be sure to disconnect the power cord from the wall outlet or turn off the circuit breaker before performing any maintenance. the unit in the COOL 1 Operate mode, temperature setting 30˚C, CLEANING THE FILTERS 1 Turn off the unit. 2 Remove the filters. to thoroughly dry inside the unit. 1 Lift the open panel. 2 Pull the air filters down to remove them. ENG- the operation and unplug the 2 Stop unit.
BEFORE CALLING FOR SERVICE The following conditions do not denote equipment malfunctions Check the following points before calling for service. UNIT DOES NOT OPERATE The unit does not operate The unit will not operate if it is turned on immediately after it is turned off. The unit will not operate immediately after the mode is changed. This is to protect the unit. Wait 3 minutes before operating the unit. • Check if the circuit breaker has tripped or the fuse has blown.
INSTALLATION MANUAL SPLIT TYPE ROOM AIR CONDITIONER SAFETY PRECAUTIONS ENG- • Installation must be made in accordance with the installation manual by qualified service personnel. Incorrect work will cause electric shock, water leak, fire. • Be sure to use the attached accessories parts and specified parts for installation. Use of other parts will cause electric shock, water leak, fire, the unit falling. • The appliance shall be installed in accordance with national wiring regulations.
NOTES ON LOCATIONS INDOOR UNIT 1. Keep the air outlet clear of any obstacle so that outgoing air flows smoothly in the entire room. 2. Make a drain hose hole for easy drainage. 3. Provide sufficient space on both sides and above the unit. 4. The air filters should be easily taken in and out. 5. Keep TV set, radio and the like 1 m or more away from the unit and the remote control. 6. Keep the air inlet clear of obstacles that could block incoming air. 7.
PIPES Max. piping length:A 10 m 15 m 15 m Model 9K-Btu/h type 12K-Btu/h type 18K 24K-Btu/h type Max. height difference:B 5m 7m 10 m Min. piping length Additional refrigerant (piping length exceeds 7.5m) 15 g/m 1m 10 g/m • Standard piping length is 7.5m. • When the outdoor unit is placed at a higher level than the indoor unit, provide a trap near the hose’s lead-in port. A Trap Use the refrigerant pipes shown in the table below. Pipe thickness Pipe size Liquid side Gas side 1/4" (ø 6.
PLACING THE MOUNTING PLATE AND MAKING A PIPING HOLE Installing the mounting plate (1) Referring to the “INSTALLATION DIMENSION OF INDOOR UNIT”, mark the location for the fixing holes and the piping hole. • Recommended fixing holes are marked in circle around the hole. (7 points) • Make sure that the mounting plate is horizontally. 1 MOUNTING PLATE (2) Secure the mounting plate to the wall with the long screws and check the stiffness.
Model 18000/24000 BTU MOUNTING PLATE Taping Hook Piping route For directions 1, 2 , 4 and 5, cut out the specific zone without leaving any sharp edge. (Keep the cut-out plate for possible future use.) Plate MOUNTING PLATE 1 2 3 Plate Plate 5 4 Plate Cut the plate along notch. Drain Hose (1) Remove the screw and pull out the drain hose. Screw Drain Cap ENG- Exchange the drain hose Drain Hose Tape (2) Pull out the drain cap.
(1) Process the end of the connecting cable for the indoor side. (2) Open the open panel. (3) Connect the cable. (4) Fix the cable with the cable cover and the short screw. (5) Close the open panel.
OUTDOOR UNIT INSTALLATION Referring to the figure, firmly fasten the outdoor unit with bolts.
CONNECTING THE PIPES TO THE OUTDOOR UNIT Piping can be made in four directions, choose whichever direction convenient according to unit’s installation condition. 1. Remove 3 screws of service panel. Slide the panel downward and detach it. Screw Pipe cover 2. Remove the knock out hole of pipe cover or unit base pan, depending on the piping direction intended. After removing the knock out hole, remove burrs and attach BUSHING B on the knock out hole to protect the edge.
AIR REMOVAL ENG- (1) Remove both valve shaft caps of the 2 and 3-way valves. (2) Remove the service port cap of the 3-way valve. (3) Connect the gauge manifold hose to the service port and the vacuum pump. Be sure that the hose end to be connected to the service port has a valve core pusher. (4) Open the gauge manifold low-pressure valve(Lo) and operate the vacuum pump for 10-15 minutes. Make sure the compound gauge reads -0.1 MPa(-76 cmHg). (5) Close the gauge manifold valve.
CONNECTING THE CABLE TO THE OUTDOOR UNIT 9K 12K-Btu/h type (1) Process the end of the connecting cable for the outdoor unit. (2) Remove the control box cover. (3) Connect the cable. (4) Put back the control box cover. (5) Double-check that the cable is securely in place.
POWER CABLING Prepare a dedicated power supply circuit. 9K-Btu/h type 12K-Btu/h type Power supply Circuit breaker 18K-Btu/h type 24K-Btu/h type 220 V - 240 V, single-phase 10 A 15 A 20 A 25 A Power supply cable Power supply Blue Brown Green/Yellow-striped ENG- • Fit a disconnect switch, having a contact separation of at least 3mm in all poles, to the electricity power line. Blue Live Green/Yellow-striped TEST RUN (1) Start the operation with the remote control.
DETACHING THE UNIT FROM THE MOUNTING PLATE Push the “ ” marks at the bottom of the indoor unit and pull the bottom of the unit. When the hooks are released from the mounting plate, support the bottom of the unit and lift the unit upwards. “ ” mark. PUMP DOWN Pump down is adopted in the case of unit removal for re-installation, abandonment, repair etc. Pump down is to collect the refrigerant into the outdoor unit.