Service manual

35
AF-R50CX
AF-R55CX
AF-R60CX
AF-R70CX
RUNNING CONDITION
Note:
1. Select mode of the Running Condition of a Room Air Conditioner.
SELECTOR .................................................................................................... HIGH COOL
THERMOSTAT .............................................................................................. 64˚F
2. Data of Performance Curve is measured between 40%RH and 70%RH.
If you measure the Room Air Conditioner above or below this rating, the data may miss the range of the
performance curve.
3. Outlet air temp. is influenced by the method of measurement. Measurement examples are shown.
4. Use power input data when checking the Running Condition.
RUNNING CONDITION FOR
MODEL AF-R60CX
PERFORMANCE CURVE
RUNNING CONDITION FOR
MODEL AF-R50CX / AF-R55CX
PERFORMANCE CURVE
Outside air temp.˚C (˚F)
Outlet air temp˚C (˚F)
25 30 35
(77) (86) (95) (104)
40
10
20
30
(50)
(68)
(86)
3
4
5
400
300
500
Line current(Amp.) Power input (W)
600
40%RH
70%RH
70%RH
40%RH
40%RH
70%RH
Outside air temp.˚C (˚F)
Outlet air temp˚C (˚F)
25 30 35
(77) (86) (95) (104)
40
10
20
30
(50)
(68)
(86)
4
5
6
500
400
600
Line current(Amp.) Power input (W)
700
40%RH
70%RH
70%RH
40%RH
40%RH
70%RH