Service manual
3-16
AY-ZP35PR
Indoor unit 
operates.
Outdoor unit 
does not 
operate tem-
porarily. 
3-time
Timer (Orange) 3 0 Dry opera-
tion
Temporary stop 
due to dehumidi-
fying operation
(Temporary stop for cycle 
protection)
-
Operation (Green)
Plasmacluster 
(Blue)
Indoor and 
outdoor units 
do not oper-
ate.
5-time
Timer (Orange) 5 0 Outdoor unit 
thermistor 
open-circuit
Heat exchanger 
thermistor open 
circuit error
(1) Check connector of 
the outdoor unit ther-
mistor for secure 
installation.
(1) Correct the instal-
lation.
Operation (Green)
Plasmacluster 
(Blue)
Timer (Orange) 1 Outdoor temper-
ature thermistor 
open circuit error
(2) Measure resistance 
of outdoor ther-
mistors.
(2) Replace the out-
door unit ther-
mistor assembly.
Operation (Green)
Plasmacluster 
(Blue)
Timer (Orange) 2 Suction ther-
mistor open cir-
cuit error
(3) Check the lead wires 
of thermistors on the 
outdoor unit control 
PWB for open-cir-
cuit.
(3) Replace the out-
door unit ther-
mistor assembly.
Operation (Green)
Plasmacluster 
(Blue)
Timer (Orange) 3 2-way valve ther-
mistor open cir-
cuit error.
(4)  No abnormality 
found in above 
inspections (1) 
through (3).
(4) Replace the out-
door unit control 
PWB assembly.
Operation (Green)
Plasmacluster 
(Blue)
Timer (Orange) 4 Discharge ther-
mistor open cir-
cuit error
Operation (Green)
Plasmacluster 
(Blue)
Timer (Orange) 5 Heat sink ther-
mistor open cir-
cuit error
Operation (Green)
Plasmacluster 
(Blue)
Indoor and 
outdoor units 
do not oper-
ate.
6-time
Timer (Orange) 6 0 Outdoor unit
DC Current
DC over current 
error
Go to “DC Over Current Error (6-0 error)”.
Operation (Green)
Plasmacluster 
(Blue)
Timer (Orange) 1 IPM pin level 
error
(1) Check the IPM is 
attached correctly to 
the outdoor unit IPM 
PWB.
(1) Replace the out-
door unit IPM PWB 
assembly.
Operation (Green)
Plasmacluster 
(Blue)
Problem 
symptom
Outdoor 
unit indi-
cation 
(LED1)
Indoor unit Malfunc-
tion No.
Content of diagnosis Check point Action
Lamp Main Sub Main Sub