CA1 Non Volatile Memory Codes
All user setting are contained within the non volatile memory, IC1002 including a number of pre-set
receiver parameters. Although these are pre-set for the model, they can be changed. Under normal
circumstances this would serve no purpose, as the circuitry to preform the various functions may not be
fitted. However, should a data corruption occur, or there is a need to modify the software, the locations
and functions are shown below. At the end of this section an explanation is given on how to set these
codes.
CA1 NVM Locations and Functions
Address ( Default
HEX ) Description Value
00 Red Colour Temperature
01 Green Colour Temperature
02 Blue Colour Temperature
03 Vertical Shift
04 Horizontal Shift
05 Vertical Amplitude
06 Vertical Slope
07 Luminance Delay - PAL
08 Luminance Delay - SECAM
09 S-Correction
0A Automatic Gain Control
0B Bit 0 :
Bit 1 : 0 = No Front AV Sockets Fitted, 1 = Front AV Socket Fitted
Bit 2 : 0 = Tuning Unlocked, 1= Tuning Locked ( Hotel Mode )
Bit 3 : 0 = All Band Tuning, 1= UHF Band Tuning Only
Bit 4 : 0 = PAL System Only, 1 = PAL and SECAM Systems
Bit 5 : 0 = Child Lock Disabled, 1 = Child Lock Activated
Bit 6 : 0 = Manual Tuning, 1 = Automatic Tuning
Bit 7 : 0 = OSD Symbols, 1 = OSD in English
0C AFT Adjustment Value for B/G and L Systems
0D AFT Adjustment Value for L’ System
0E Maximum Volume Limit
0F Firm
10 Red Colour Temperature
11 Green Colour Temperature
12 Blue Colour Temperature
13 Vertical Shift
14 Horizontal Shift
15 Vertical Amplitude
16 Vertical Slope