Specifications

3-40 Chapter 3: 7401-2xxx/3xxx Hardware Installation
7401-9512 LCD No-Cabinet (15-inch)
The15inchLCDNoCabinetmodelispurchasedbycustomerswho
designtheirownenclosurestomeettheirspecificneeds.Thissection
providesinformationthatmustbeconsideredwhendesigning
enclosures.
Installation Guidelines
Topreventmoisturefromenteringsys tem,thefrontofthedisplay
mustbeinclosecontactwiththeopeningintheenclosure.
Withineverycustomenclosure,theElectronicsBoxBackCover
MUSTremaininstalledbecauseithelpsdissipatetheheat
generatedbytheCPU.
Adequateventilationmustbe
providedineverycustomenclosure.
Themaximumallowableambienttemperaturewithinany
enclosureis45
o
C(113
o
F).
Topreventaccidentalshorts,thepowersupplyandanyother
peripheralswithintheenclosuremustbemountedsecurelyand
withinreachofthedisplay’sconnectors.
Thismodelcomeswithamotionsensorthatisattheendofa
381mm(15in.)cable.Whenusingthe
motionsensor,itmustbe
mountedbetween25and76mm(1to3in.)belowthebottomofthe
displayandcenteredalongthewidthofthedisplay.
Complianceofthisdevicewithregulatoryrequirementsmustbe
verifiedintheenduseapplication.
Thisdeviceisacomponent
whichrequiresasuitableenclosurein
itsenduseapplication.Theenduseproductinwhichthis
componentisusedshouldbecertifiedinaccordancewithUL1950,
EN60950,IEC950orotherapplicablesafetystandard.
NCRdisplaysarenotdesignedforhorizontalorinverteduse.NCR
displaysmustbemounted
nomorethan40
o
forwardorbackwardfrom
horizontal.Failuretofollowthisguideline couldresultinoverheating.