Instruction manual

The two shorter prongs should not show
continuity (Figure 706).
7-4 Wiring Diagram Location
1) Using a screwdriver, open the control box
(Figure 707).
2) A tag tied to wires indicates the control box
type, L10.3B, and wiring diagram, #34427
(Figure 708).
3) A full size diagram should be folded and
tucked in place next to the relays. Check that
the full size diagram matches the tag (Figure
709).
7-5 Stator/Winding Check
1) With an ohm-meter, measure the resistance
of the starting winding W/Z by placing test
probes on Position 1(W) and Position 2(Z) of
terminal board M1 (3.9 ohms is normal.
Figure 711 (on the next page), shows 4.0-0.2
= 1.73 ohms,OK). This is found on the wiring
diagram #34427. If the connection is open,
the stator must be replaced.
53
NOTE:
If either of the shorter prongs show continuity to
ground, a short circuit has occurred and must be
fixed. It is possible that the plug is wired incor-
rectly or the insulation is cut. Open the plug and
investigate. Also check the cord grip.
Figure 706
Figure 707
Figure 708
Figure 709
NOTE:
When using an ohm-meter, deduct the test probe
resistance from any reading for accuracy. Shown
as 0.2 ohms (Figure 710).
Figure 710