Instruction manual
52
7) CONTROL BOX XE301P
7-1 Tools Required
- Volt/Ohm meter (left in Figure 701)
- Digital Capacitor meter (up to 275uF)
- 2 insulated screwdrivers
7-2 Control Box Cover Inspection
1) Check that all labels are legible and in the
right place (Figure 702). If not, replace
those labels. See sec. 9-2 for correct
location and code.
2) Check that the emergency stop button
functions normally. (Figure 703). Press it to
lock in the "Off" position. Twist it to check
that it springs open into the "On" position.
Check that it is not loose. If it is, open the
cover and tighten the 2 screws that hold it in
place.
3) Check that the protective cover around the
emergency stop button is in good condition
and is not loose. Replace it if necessary.
The 3 screws must be tightened and have
silicone applied to seal against water entry.
4) Check that the voltage indicator light is not
damaged (Figure 704).
7-3 Ground (Cord/Plug) Check
1) With an ohm meter, check each prong to the
case of the TIRAK. The long ground prong
should show continuity (Figure 705).
NOTE:
All of the following checks are done without
power to the motor or hoist.
Figure 701
Figure 702
Figure 703
Figure 704
Figure 705