Service manual

11
29H-FG5RU
11-1
11-2
ITEM EEPROM SETTING DATA RANGE IC OSD INITIAL SETTING DATA
DATA
S359 EQ3K-MS 0...31 DSP EQ3K-MS 12 17
S360 EQ8K-MS 0...31 DSP EQ8K-MS 12 20
S361 BASS-NW 0...31 DSP BASS-NW 16 31
S362 TREB-NW 0...31 DSP TREB-NW 16 25
S363 EQ100-NW 0...31 DSP EQ100-NW 12 13
S364 EQ300-NW 0...31 DSP EQ300-NW 12 16
S365 EQ1K-NW 0...31 DSP EQ1K-NW 12 19
S366 EQ3K-NW 0...31 DSP EQ3K-NW 12 16
S367 EQ8K-NW 0...31 DSP EQ8K-NW 12 13
S368 BASS-CT 0...31 DSP BASS-CT 16 31
S369 TREB-CT 0...31 DSP TREB-CT 16 25
S370 IDMOD-SE 0
3 DSP IDMOD-SE 0 0
S371 BPR-VOL 0
60 DSP BPR-VOL 20 30
S372 DEMUT-DLAY 0
16 DSP DEMUT-DLAY 8 8
S373 AV-OUT LV 0
255 DSP AV-OUT LV 16 18
Setting Mode 3-2
PIF ADJUSTMENT
No.
Adjustment point
Adjustment condition/procedure Waveform or remarks
RF-AGC
TAKE OVER
POINT AD-
JUSTMENT
(I
2
C BUS
CONTROL)
1
1. Receive "PAL COLOR BAR" signal.
Signal Strength: 54 ± 1dB_V (75 ohm termination)
2. Connect the oscilloscope to TP53 (Tuner's AGC
Terminal) as shown in figure 3-1.
3. Select "RF-AGC" item in the Adjustment Mode.
Adjust the "RF-AGC" bus data to obtain the Tuner
output pin drop 0.1V ~ 1.0V below maximum volt-
age.
4. Change the antenna input signal to 63 ~ 67dB_V,
and make sure there is no noise.
5. Set the RF AGC to 0 - 6 V with no saturation with
the waveform.
6. Turn up the input signal to 90 ~ 95 dB_B to be sure
that there is no cross modulation beat.
Fig. 3