Service manual

6
GB
6
Power Supply
FD1-11
230Vac±10%,
50/60Hz, Operating 3.2W, Standby 0.9W
Measurement Range
-50…120°C, -55…240°F
-50 / -9.9…19.9 / 80°C (NTC 10K Only)
Relay Output
Compressor - 16(8) A 240Vac
Defrost - 16(4) A 240Vac
Measurement Accuracy
<0.5°C within the measurement range
Evap. Fan - 16(4) A 240Vac
Auxiliary Loads 1 - 8(2) A 240Vac
Input
NTC 10KΩ@25°C
CE (Reference norms)
EN60730-1; EN60730-2-9
EN55022 (Class B)
EN50082-1
Parameters should not be changed unless you have an understanding of their purpose and
the following instructions are fully understood.
To gain access to the parameters use the ‘Adjustment Mode’. This is accessed by pressing
and releasing the switch. After selecting this mode press and hold and together
for 5 seconds. The first parameter will show on the display.
Using the and switches you can scroll through all parameters and their values.
If you wish to change a parameter value press and release the switch when one the
desired mnemonic. Once selected in this way use the and switches to modify. When
the new reuired value is shown it will be saved by pressing and relaeasing the switch.
After which the display will show the next parameter.
To exit this mode or revert to normal operating mode, press and together then
release.
If at any point no buttons are pressed for 30 seconds without saving a new value the display will
return to the standard temperature display without changes being made.