Service manual
R-21HT
R-21HV
15
TEST PROCEDURES
PROCEDURE
LETTER
COMPONENT TEST
7) Reconnect the power supply cord after the outer case is installed.
8) Run the oven and check all functions.
2. Control Unit.
The following symptoms indicate a defective control unit. Before replacing the control unit, perform
the Key unit test (Procedure J) to determine if control unit is faulty.
2-1 In connection with pads.
a) When touching the pads, a certain group of pads do not produce a signal.
b) When touching the pads, no pads produce a signal.
2-2 In connection with indicators
a) At a certain digit, all or some segments do not light up.
b) At a certain digit, brightness is low.
c) Only one indicator does not light.
d) The corresponding segments of all digits do not light up; or they continue to light up.
e) Wrong figure appears.
f) A certain group of indicators do not light up.
g) The figure of all digits flicker.
2-3 Other possible problems caused by defective control unit.
a) Buzzer does not sound or continues to sound.
b) Clock does not operate properly.
c) Cooking is not possible.
When testing is completed,
1) Disconnect the power supply cord, and then remove outer case.
2) Open the door and block it open.
3) Discharge high voltage capacitor.
4) Reconnect all leads removed from components during testing.
5) Re-install the outer case (cabinet).
6) Reconnect the power supply cord after the outer case is installed.
7) Run the oven and check all functions.
1. Disconnect the power supply cord, and then remove outer case.
2. Open the door and block it open.
3. Discharge high voltage capacitor.
4. If the display fails to clear when the STOP/CLEAR pad is depressed, first verify the flat ribbon cable
is making good contact, verify that the door sensing switch (stop switch) operates properly; that is
the contacts are closed when the door is closed and open when the door is open. If the door
sensing switch (stop switch) is good, disconnect the flat ribbon cable that connects the key unit to
the control unit and make sure the door sensing switch is closed (either close the door or short the
door sensing switch connecter). Use the Key unit matrix indicated on the control panel schematic
and place a jumper wire between the pins that correspond to the STOP/CLEAR pad making
momentary contact. If the control unit responds by clearing with a beep the key unit is faulty and
must be replaced. If the control unit does not respond, it is faulty and must be replaced. If a specific
pad does not respond, the above method may be used (after clearing the control unit) to determine
if the control unit or key pad is at fault.
5. Reconnect all leads removed from components during testing.
6. Re-install the outer case (cabinet).
7. Reconnect the power supply cord after the outer case is installed.
8. Run the oven and check all functions.
R-21HT R-21HV
J KEY UNIT TEST
5
6
3
4
1
2
7
8
9
0
SELECTA
TIME
STOP/
CLEAR
START SET
CHECK
SIGNAL
DOUBLE
QUANTITY
EXPRESS
DEFROST
G12
G11
G10
G 9
G 1 G 2 G 3 G 4 G 5 G 6 G 7 G 8
5
6
3
4
1
11131519
12141620
17
18
2
7
8
9
0
SELECTA
TIME
SELECTA
POWER
STOP/
CLEAR
START SET
CHECK
SIGNAL
DOUBLE
QUANTITY
EXPRESS
DEFROST
G12
G11
G10
G 9
G 1 G 2 G 3 G 4 G 5 G 6 G 7 G 8