Operator`s manual
OPERATION
Form 169000 / 169040 43 Revision C
6.6.2.3 M200
CAUTION
To prevent accidental movement of
windrower, place all controls in NEUTRAL or
in PARK, engage park brake (if applicable),
shut off engine, and remove key.
The Windrower requires four hoses to run an
A40-D header. If required, configure the M200
to run an A40-D auger header by installing Kit
B4651. The Kit includes the additional hose,
hardware, and installation instructions.
a. Disengage rubber latch (A), and open driveline
shield (B).
b. Remove the cap (C) from electrical connector,
and remove connector from support bracket.
c. Disengage and rotate lever (D) counter
clockwise to “fully up” position to release the
hose bundle (E).
d. Move hose/electrical bundle (E) to header.
e. Route bundle (E) from windrower through
support (F) and access hole (G) in header frame
alongside existing hose bundle (H) from header.
f. Remove cover on header electrical receptacle
(J).
g. Push connector onto receptacle, and turn collar
on connector to lock it in place.
h. Attach cover to mating cover on windrower
wiring harness.
i. Remove caps from hydraulic couplers, and
clean if necessary.
(continued next page)
G
H
J
E
F
A
B
D
C
E