Service manual

6
14A1-RU
14A2-RU
6-2
6-1
INITIAL SETTING
(1). In service mode, After execute select POS 1, store the following tuning data in EEPROM.
MCL1
CH-NO Fv (MHz) SOUND SYS
MCL1
CH-NO Fv (MHz) SOUND SYS
0
1 48.25 B/G
2 62.25 B/G
3 77.25 D/K
4 175.25 B/G
5 182.25 B/G
6 183.25 D/K
7 191.25 D/K
8 196.25 B/G
9 199.25 M
10 210.25 B/G
11 224.25 B/G
12 471.25 B/G
13 487.25 I
14 503.25 B/G
15 575.25 B/G
16 583.25 B/G
17 599.25 B/G
18 621.25 M
19 639.25 D/K
20 703.25 B/G
21 735.25 I
22 767.25 B/G
23 815.25 B/G
24 855.25 I
25 855.25 B/G
26 55.25 M
27 83.25 M
28 183.25 M
29 193.25 M
30 217.25 M
31 471.25 M
32 477.25 M
33 693.25 M
34 885.25 M
35 112.25 B/G
36 168.25 B/G
37
38 294.25 B/G
39 463.25 B/G
40
41 647.25 B/G
42 663.25 B/G
43 679.25 B/G
44 174.95 B/G
45 175.55 B/G
ITEMS DATA SETTING
LAST PROGRAM/CHANNEL 1
FLASHBACK PROGARM/CH 1
DIGIT 1
C-SYSTEM AUTO
S-SYSTEM D/K
SKIP OFF
AFC ON
VOLUME 1
CONTRAST 60 (MAX)
COLOUR 0 (CENTER)
BRIGHTNESS 0 (CENTER)
TINT 0 (CENTER)
SHARPNESS 0 (CENTER)
WHITE TEMP STANDARD
REMINDER TIMER In-active, "--:--"
ON TIMER In-active, "--:--"
OFF TIMER In-active, "--:--"
LAST POWER POWER-ON
LANGUAGE RUSSIAN
BLUE BACK MUTE OFF
HOTEL MODE OFF
0 CHANNEL SKIP ON
SHIPPING SETTING & CHECKING
(1) The following default data has been factory-set for the E
2
PROM.
*1: Please refer defaults for LANGUAGE and SOUND SYSTEM per MODEL as follows,
MODEL LANGAUGE SOUND SYSTEM
RU RUSSIAN D/K
MODEL Geomagnetism (H,V) nT Background Lang. S-SYS
J (RU) "45,000" "20,000" 7500K RUSSIAN D/K
FACTORY SETTINGS BY MODELS (Reference: Geomagnetism Adjustment)
*OSD LANG MUST BE SET IN SERVICE MODE,BUT IT'S BETTER TO WRITE IN EEPROM.
LANGUAGE QUANTITIES:ENGLISH/RUSSIAN