Service manual
47
13VT-R100/R150
13VT-CR10
NO
CAPSTAN SERVO TROUBLESHOOTING FLOW CHART NO.1-13
Capstan servo does not function.
YES
YES
Check X7701, C7708 and
C7707.
Is there 14MHz oscillation at pin
(37) and (38) of IC2001?
When playback using the
recorded tape from a normal set,
does capstan servo functioning?
When using the same tape, is
there a PB CTL OUT signal
detected at pin (76) of IC2001?
Is there a normal capstan FG IN
signal at pin (67) of IC2001?
Is there a normal capstan FG at
pin (6) of AC connector?
Check capstan FG line.
Check IC2001.
Check IC2001.
Are the duty ratio of CAP AFC
PWM at pin (31) and CAP APC
PWM at pin (33) of IC2001
change according to the number
of capstan motor rotation?
(slowing down the capstan motor
by touching with your finger)
Check connection between AA
and MH connector. Clean the
A/C Head. Check the azimuth
and height of the A/C Head.
Check connection between pin
(5) and (6) of AA connector and
pin (74) and (75) of IC2001.
YES
YES
YES
Is the voltage at pin (4) of AC
connector change according to
number of motor rotation?
Check connection between AC
and MC connector. Change
capstan motor.
YES
Check connection between pin
(31) and (33) of IC2001 and pin
(4) of AC connector.
YES YES
At the REC mode, is there a REC
CTL signal detected at pin (74)
and (75) of IC2001?
YES
Is there a REC CTL signal
detected at pin (5) and (6) of AA
connector?
YES
YES
Check connection between AA
and MH connector. Check the
cleanliness, azimuth and height
of A/C Head.
Does drum servo functioning?
Change A/C Head.
NO
NO
NO
NO
NO
NO
See FLOW CHART NO. 1-12.
NO
Check IC2001.
NO
Check the REC CTL signal
line.
NO