Service manual

51
13VT-N100
13VT-N150
13VT-CN10
NO
NO
NO
NO
FLOW CHART NO.2-1
FLOW CHART NO.2-2
Set not operating
YES
YES
YES
YES
YES
Is 120V AC applied to
line between K701 and
K702?
Pin (7) of T701 voltage
check about: 170V DC
at 120V AC
+B voltage check
about: 115.0V (C730
side)
Does pulse waveform
exist at line between pin
(1) and (2) of IC701?
Check D701 thru
D704, L701, and
R701.
Is AC cord connected?
Is 170V DC applied to
C705?
Check T701 and
adjacent parts.
Is 16V DC applied to
pin (4) of IC701?
Check IC701, R717.
Check IC701 and
adjacent parts.
CRT connector
GC1~GC5 bias check
The Fuse is again
blown out.
D701, D702, D703,
D704, D705
Connect AC cord. F701 Check
Normal
Normal
IC701, Check
Normal
Abnomal
IC401 (iX3253CE)
Normal
Normal
C880
Blown out
Replace the Fuse
Abnormal
R701
Abnormal
IC701, D727
Normal
Q601, Q602
and R603
AC cord broken.
NO RASTER