CAPSTAN SERVO TROUBLESHOOTING FLOW CHART NO.1-11
YES
YES
YES
YES
NO
NO
YES
YES
YES
YES
YES
YES
YES
YES
NO
Is pin (78) of IC2001
normal?
Replace the capstan
motor.
Replace IC2001.
Replace IC2001.
Replace the FFC AA-MH.
Check X7701, C7707 and
C7706.
Check the capstan FG
signal line between AC
connector and IC2001.
Does there appear the
capstan FG signal at pin
(87) of IC2001?
Is there the capstan
control voltage applied to
pin (4) of AC connector?
Check the composite
sync. signal at pin (41) of
IC401, Q404 and Q428
up to pin (56) of IC2001.
Replace IC2001.
Replace A/C head.
Check " A "
Check " B "
In case of NO GOOD
Does there appear the V-
sync. at pin (56) at
IC2001?
Is there REC CTL signal
output at pins (94), (95) of
IC2001?
Is there capstan control
signal at pin (76) of
IC2001?
Are REC and /or PB
mode inoperative?
Is the FFC AA-MH
normal?
Does the A/C head
operate normally?
Adjust the height of the
A/C head.
Does PB CTL signal
appear at pin (97) of
IC2001?
Does CTL amplifier circuit
of IC2001 (pins (95) to
(97)) operate normally?
(Does the noise appear at
pin (97) when touch
R7759 by hand?)
Only PB mode inoperative. Only REC mode inoperative.
A
B
Is there 16MHz oscillation
at pins (38) and (39) of
IC2001.
Capstan servo does not function.